CoChat

Incidence and Predictors of Perioperative Complications With Transvenous Lead Extractions: Real-World Experience With National Cardiovascular Data Registry

Sood, Nitesh, Martin, David T., Lampert, Rachel, Curtis, Jeptha P., Parzynski, Craig, Clancy, Jude · 2018 · Circulation: Arrhythmia and Electrophysiology
Cited by 192

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Transvenous lead extraction is an integral part of management of patients with cardiovascular implantable electronic devices. Real-world incidence and predictors of perioperative complications in extractions involving implantable cardioverter-defibrillator leads have not been described in detail. Methods and Results: Data from the National Cardiovascular Data Registry Implantable Cardioverter-Defibrillator Registry were analyzed. Lead extraction was defined as removal of leads implanted for >1 year. Predictors of major perioperative complications for all extraction procedures (11 304) and for high-voltage lead (8362, 74%), across 762 centers, were analyzed using univariate and multivariate logistic regression. Major complication occurred in 258 (2.3%) extraction procedures. Of these 258 with a complication, 41 (16%) required urgent cardiac surgery. Of these 41, 14 (34%) died during surgery. Among the total 98 (0.9%) deaths reported, 18 (0.16% of total) occurred during transvenous lead extraction. In multivariable logistic regression analysis, female sex, admission other than electively for procedure, ≥3 leads extracted, longer implant duration, dislodgement of other leads, and patient’s clinical status requiring lead extraction (infection/perforation) were associated with increased risk of complications. Smaller lead diameter, flat versus round coil shape, and greater proximal surface coil area were multivariate predictors of major perioperative complications specific to high-voltage leads. Conclusions: The rate of major complications and mortality with transvenous lead extraction is similar in the real-world outcomes to that reported in recent single-center studies from high-volume centers. There is significant risk of urgent cardiac surgery, which carries a high mortality, and planning for appropriate cardiothoracic surgery backup is imperative.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.116.004768

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Metadata

Authors
Sood, N., Martin, D. T., Lampert, R., Curtis, J. P., Parzynski, C., & Clancy, J.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2018-02
Volume
11
Issue
2
Pages
e004768-e004768
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2790863376
Cited by
192
References
2
FWCI
12.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incidence and Predictors of Perioperative Complications With Transvenous Lead Extractions: Real-World Experience With National Cardiovascular Data Registry. https://app.cochat.ai/papers/10.1161/circep.116.004768
The paper
Sood, N., Martin, D. T., Lampert, R., Curtis, J. P., Parzynski, C., & Clancy, J. (2018). Incidence and Predictors of Perioperative Complications With Transvenous Lead Extractions: Real-World Experience With National Cardiovascular Data Registry. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.116.004768

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.