Incidence and Predictors of Perioperative Complications With Transvenous Lead Extractions: Real-World Experience With National Cardiovascular Data Registry
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Background: Transvenous lead extraction is an integral part of management of patients with cardiovascular implantable electronic devices. Real-world incidence and predictors of perioperative complications in extractions involving implantable cardioverter-defibrillator leads have not been described in detail. Methods and Results: Data from the National Cardiovascular Data Registry Implantable Cardioverter-Defibrillator Registry were analyzed. Lead extraction was defined as removal of leads implanted for >1 year. Predictors of major perioperative complications for all extraction procedures (11 304) and for high-voltage lead (8362, 74%), across 762 centers, were analyzed using univariate and multivariate logistic regression. Major complication occurred in 258 (2.3%) extraction procedures. Of these 258 with a complication, 41 (16%) required urgent cardiac surgery. Of these 41, 14 (34%) died during surgery. Among the total 98 (0.9%) deaths reported, 18 (0.16% of total) occurred during transvenous lead extraction. In multivariable logistic regression analysis, female sex, admission other than electively for procedure, ≥3 leads extracted, longer implant duration, dislodgement of other leads, and patient’s clinical status requiring lead extraction (infection/perforation) were associated with increased risk of complications. Smaller lead diameter, flat versus round coil shape, and greater proximal surface coil area were multivariate predictors of major perioperative complications specific to high-voltage leads. Conclusions: The rate of major complications and mortality with transvenous lead extraction is similar in the real-world outcomes to that reported in recent single-center studies from high-volume centers. There is significant risk of urgent cardiac surgery, which carries a high mortality, and planning for appropriate cardiothoracic surgery backup is imperative.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wilkoff, B. L., Love, C. J., Byrd, C. L., Bongiorni, M. G., Carrillo, R. G., Crossley, G. H., Epstein, L. M., Friedman, R. A., Kennergren, C. E. H., Mitkowski, P., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.05.020 · Cited by 1,024
Lead Extraction in the Contemporary Setting: The LExICon Study
Wazni, O., Epstein, L. M., Carrillo, R. G., Love, C., Adler, S. W., Riggio, D. W., Karim, S. S., Bashir, J., Greenspon, A. J., DiMarco, J. P., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.070 · Cited by 584
Superior Vena Cava Defibrillator Coils Make Transvenous Lead Extraction More Challenging and Riskier
Epstein, L. M., Love, C. J., Wilkoff, B. L., Chung, M. K., Hackler, J. W., Bongiorni, M. G., Segreti, L., Carrillo, R. G., Baltodano, P., Fischer, A., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.12.014 · Cited by 467
Increasing rates of cardiac device infections among medicare beneficiaries: 1990–1999
Cabell, C. H., Heidenreich, P. A., Chu, V. H., Moore, C. M., Stryjewski, M. E., Corey, G. R., & Fowler, V. G. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.06.005 · Cited by 397
VOIGT, A., SHALABY, A., & SABA, S. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02569.x · Cited by 396
The National Cardiovascular Data Registry (NCDR) Data Quality Brief
Messenger, J. C., Ho, K. K. L., Young, C. H., Slattery, L. E., Draoui, J. C., Curtis, J. P., Dehmer, G. J., Grover, F. L., Mirro, M. J., Reynolds, M. R., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.020 · Cited by 367
Self-citationClinical Study of the Laser Sheath for Lead Extraction: The Total Experience in the United States
BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., & REISER, C. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.t01-1-00804.x · Cited by 308 · cited 1×
“Combined silicone/polyurethane/ eTFE 952 (9) 35 (13.”
Jones, S. O., Eckart, R. E., Albert, C. M., & Epstein, L. M. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.01.009 · Cited by 216 · cited 1×
“Combined silicone/polyurethane 1069 (10) 18 (7) 0.”
Brunner, M. P., Cronin, E. M., Duarte, V. E., Yu, C., Tarakji, K. G., Martin, D. O., Callahan, T. D., Cantillon, D. J., Niebauer, M. J., Saliba, W. I., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.01.016 · Cited by 215
Self-citationA single-centre experience of over one thousand lead extractions
Kennergren, C., Bjurman, C., Wiklund, R., & Gabel, J. (2009) · Europace · doi:10.1093/europace/eup054 · Cited by 205
Long-Term Mortality After Transvenous Lead Extraction
Maytin, M., Jones, S. O., & Epstein, L. M. (2012) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.111.965277 · Cited by 186
Pacemaker and ICD Generator Reliability: Meta-analysis of Device Registries
Maisel, W. H. (2006) · JAMA · doi:10.1001/jama.295.16.1929 · Cited by 170
Lead Extraction Is Preferred for Lead Revisions and System Upgrades: When Less Is More
Maytin, M., Epstein, L. M., & Henrikson, C. A. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.110.954107 · Cited by 131
Hauser, R. G., McGriff, D. M., & Kallinen, L. M. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.019 · Cited by 128
Epstein, L. M., BYRD, C. L., Wilkoff, B. L., Love, C. J., Sellers, T. D., Hayes, D. L., & Reiser, C. (1999) · Circulation · doi:10.1161/01.cir.100.5.516 · Cited by 125
Hauser, R. G. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.02.077 · Cited by 121
Agarwal, S. K., Kamireddy, S., Němec, J., Voigt, A., & Saba, S. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01283.x · Cited by 109
Laser Lead Extraction: Predictors of Success and Complications
Roux, J.-F., Pagé, P., Dubuc, M., Thibault, B., Guerra, P. G., Macle, L., Roy, D., Talajic, M. R., & Khairy, P. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00652.x · Cited by 105 · cited 1×
“Combined silicone/polyurethane 1069 (10) 18 (7) 0.”
Maytin, M., Love, C. J., Fischer, A., Carrillo, R. G., Garisto, J. D., Bongiorni, M. G., Segreti, L., John, R. M., Michaud, G. F., Albert, C. M., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.03.058 · Cited by 89
Franceschi, F., Thuny, F., Giorgi, R., Sanaa, I., Peyrouse, E., Assouan, X., Prévôt, S., Bastard, E., Habib, G., & Deharo, J. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.045 · Cited by 88
Hammill, S. C., Kremers, M. S., Stevenson, L. W., Kadish, A. H., Heidenreich, P. A., Lindsay, B. D., Mirro, M. J., Radford, M. J., Wang, Y., Curtis, J. P., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.07.015 · Cited by 76
Self-citationBrunner, M. P., Cronin, E. M., Jacob, J., Duarte, V. E., Tarakji, K. G., Martin, D. O., Callahan, T. D., Borek, P., Cantillon, D. J., Niebauer, M. J., et al. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.06.021 · Cited by 72
Self-citationLaser Lead Extraction: Is There a Learning Curve?
Ghosh, N., Yee, R. K., Klein, G. J., Quantz, M., Novick, R. J., Skanes, A. C., & Krahn, A. D. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.09368.x · Cited by 50
Roeffel, S. M., Bracke, F. A. L. E., Meijer, A., van Gelder, B., van Dantzig, J. M., BOTMAN, C. J., & Peels, K. H. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.01583.x · Cited by 49
Arujuna, A., Williams, S. E., Whittaker, J., Shetty, A., Roy, D., Bostock, J., Kirubakaran, S., O'Neill, M. D., Gill, J. S., Cooklin, M., et al. (2012) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2011.02863.x · Cited by 40
Safety and Effectiveness of Transvenous Lead Extraction in Octogenarians
Pelargonio, G., Narducci, M. L., Russo, E., Casella, M., Santangeli, P., Canby, R. C., Al‐Ahmad, A., Price, L. D., Biase, L. D., KWARK, C. J., et al. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02372.x · Cited by 30
Stiffness of the Distal Tip of Bipolar Pacing Leads
CAMERON, J., Mond, H. G., CIDDOR, G., HARPER, K., & MCKIE, J. (1990) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1990.tb06916.x · Cited by 25 · cited 2×
“Manufacturer advisory/recall 4158 (38) 75 (29) 0.”
Assayag, P., Thuaire, C., Benamer, H., Sebbah, J., Leport, C., & Brochet, É. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb06828.x · Cited by 24
Metadata
- Authors
- Sood, N., Martin, D. T., Lampert, R., Curtis, J. P., Parzynski, C., & Clancy, J.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2018-02
- Volume
- 11
- Issue
- 2
- Pages
- e004768-e004768
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2790863376
- Cited by
- 192
- References
- 28
- FWCI
- 12.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.