Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force–Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain

Open access
El Haddad, Milad, Taghji, Philippe, Phlips, Thomas, Wolf, Michael, Demolder, Anthony, Choudhury, Rajin, Knecht, Sébastien, Vandekerckhove, Yves, Tavernier, Rene, Nakagawa, Hiroshi, Duytschaever, Mattias · 2017 · Circulation: Arrhythmia and Electrophysiology

Abstract

Background—: Pulmonary vein reconnection (PVR) still determines recurrences of atrial fibrillation after contact force (CF)–guided pulmonary vein isolation. We studied whether acute PVR (adenosine and waiting time) and late PVR (at repeat) are explained by incomplete transmurality and contiguity within the deployed radiofrequency circle. Methods and Results—: We analyzed 42 CF-guided ipsilateral pulmonary vein isolation procedures. For each radiofrequency tag within the circle, we collected data reflecting lesion depth (time of application, power, impedance drop [Δ-Imp], CF, force–time integral [FTI], and ablation index [AI]) and contiguity (automated interlesion distance [ILD]). Ablation line contiguity index (ALCI) was developed as a novel automated algorithm combining depth and contiguity into one single criterion. Each circle was subdivided into 10 segments. For each segment, we determined its weakest link by annotating time min , power min , Δ-Imp min , CF min , FTI min , AI min , ILD max , and ALCI min . Compared with segments without PVR (n=758), PVR segments (n=44) were characterized by lower Δ-Imp min (4.8 versus 7.4 Ω), CF min (8.5 versus 11.8 g), FTI min (351 versus 473 gs), AI min (367 versus 408 arbitrary unit [au]), and higher ILD max (6.8 versus 5.5 mm). ALCI min was significantly lower in segments with PVR (74% versus 104%; P <0.001) and was associated with the highest accuracy to predict durable segments (area under the curve=0.73). Conclusions—: In CF-guided pulmonary vein isolation, PVR is explained by lack of both lesion depth and contiguity within the deployed radiofrequency circle. ALCI, a novel measure combining contiguity and depth, is the most accurate predictor for durable segments. By avoiding weak links in the ablation chain, ALCI-guided ablation is expected to improve success rate of point-by-point radiofrequency ablation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.116.004867

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 160

Metadata

Authors
El Haddad, M., Taghji, P., Phlips, T., Wolf, M., Demolder, A., Choudhury, R., Knecht, S., Vandekerckhove, Y., Tavernier, R., Nakagawa, H., & Duytschaever, M.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2017-04
Volume
10
Issue
4
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2604376515
Cited by
160
References
2
FWCI
12.68
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force–Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain. https://app.cochat.ai/papers/10.1161/circep.116.004867
The paper
El Haddad, M., Taghji, P., Phlips, T., Wolf, M., Demolder, A., Choudhury, R., Knecht, S., Vandekerckhove, Y., Tavernier, R., Nakagawa, H., & Duytschaever, M. (2017). Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force–Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.116.004867

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.