Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 358

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the ‘CLOSE’-protocol

Open access
Phlips, Thomas, Taghji, Philippe, El Haddad, Milad, Wolf, Michael, Knecht, Sébastien, Vandekerckhove, Yves, Tavernier, René, Duytschaever, Mattias · 2018 · EP Europace

Abstract

Aims: We have recently shown that a contact force (CF)-guided ablation protocol respecting region-specific criteria of lesion contiguity and lesion depth ('CLOSE' protocol) is associated with high incidence of acute durable pulmonary vein (PV) isolation (PVI) and a high single-procedure arrhythmia-free survival at 1 year. In the present study, we compared efficiency, safety, and efficacy of 'CLOSE'-guided PVI to conventional CF-guided PVI (CONV-CF). Methods and results: Fifty consecutive paroxysmal atrial fibrillation (AF) patients underwent PV encircling using a CF-sensing catheter targeting an interlesion distance (ILD) ≤6 mm and ablation index (AI) ≥400 and ≥550 at posterior and anterior wall ('CLOSE' group). Results were compared to the last 50 patients undergoing 'CONV-CF'. All patients underwent adenosine testing after PVI. Arrhythmia recurrence was defined as any atrial tachyarrhythmia (ATA) >30 s on Holter at 3, 6, and 12 months. Clinical characteristics did not differ. Contact force variability was comparable in between both groups (proportion of applications with intermittent contact 2% in 'CLOSE' vs. 1% in CONV-CF, P = 0.67). In the 'CLOSE' group, procedure time and radiofrequency (RF) time per circle were shorter (respectively 149 ± 33 min vs. 192 ± 42 min, P < 0.0001 and 18 ± 4 min vs 28 ± 7.5 min, P < 0.0001) and incidence of adenosine-proof isolation was higher (97% vs. 82%, P < 0.001). No complications were observed in the 'CLOSE' group, one tamponade in the 'CONV-CF' group. At 12 months, single-procedure freedom from ATA was 94% in 'CLOSE' vs. 80% in 'CONV-CF' group (P < 0.05). In both groups, the majority of reconnections at repeat were associated with either ILD > 6 mm and/or AI < 400/550 (100% vs. 83%, P = 0.99). Conclusion: 'CLOSE'-guided PVI improves procedural and 1 year outcome in CF-guided PVI while shortening procedure time. Improvement cannot be explained by differences in CF variability and is most likely due to the strict application of criteria for contiguity and ablation index. A randomized controlled trial is needed to exclude the possible contribution of a learning curve.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eux376

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 358

Metadata

Authors
Phlips, T., Taghji, P., El Haddad, M., Wolf, M., Knecht, S., Vandekerckhove, Y., Tavernier, R., & Duytschaever, M.
Venue
EP Europace
Published
2018-01-04
Volume
20
Issue
FI_3
Pages
f419-f427
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2782496478
Cited by
358
References
19
FWCI
24.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the ‘CLOSE’-protocol. https://app.cochat.ai/papers/10.1093/europace/eux376
The paper
Phlips, T., Taghji, P., El Haddad, M., Wolf, M., Knecht, S., Vandekerckhove, Y., Tavernier, R., & Duytschaever, M. (2018). Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the ‘CLOSE’-protocol. EP Europace. https://doi.org/10.1093/europace/eux376

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.