The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Electrical Substrate Elimination in 135 Consecutive Patients With Brugada Syndrome
Abstract
Background—: There is emerging evidence that localization and elimination of abnormal electric activity in the epicardial right ventricular outflow tract may be beneficial in patients with Brugada syndrome. Methods and Results—: A total of 135 symptomatic Brugada syndrome patients having implantable cardiac defibrillator were enrolled: 63 (group 1) having documented ventricular tachycardia (VT)/ventricular fibrillation (VF) and Brugada syndrome–related symptoms, and 72 (group 2) having inducible VT/VF without ECG documentation at the time of symptoms. About 27 patients of group 1 experienced multiple implantable cardiac defibrillator shocks for recurrent VT/VF episodes. Three-dimensional maps before and after ajmaline determined the arrhythmogenic electrophysiological substrate (AES) as characterized by prolonged fragmented ventricular potentials. Primary end point was identification and elimination of AES leading to ECG pattern normalization and VT/VF noninducibility. Extensive areas of AES were found in the right ventricle epicardium, which were wider in group 1 ( P =0.007). AES increased after ajmaline in both groups ( P <0.001) and was larger in men ( P =0.008). The increase of type-1 ST-segment elevation correlated with AES expansion ( r =0.682, P <0.001). Radiofrequency ablation eliminated AES leading to ECG normalization and VT/VF noninducibility in all patients. During a median follow-up of 10 months, the ECG remained normal even after ajmaline in all except 2 patients who underwent a repeated effective procedure for recurrent VF. Conclusions—: In Brugada syndrome, AES is commonly located in the right ventricle epicardium and ajmaline exposes its extent and distribution, which is correlated with the degree of coved ST-elevation. AES elimination by radiofrequency ablation results in ECG normalization and VT/VF noninducibility. Substrate-based ablation is effective in potentially eliminating the arrhythmic consequences of this genetic disease. Clinical Trial Registration—: URL: https://clinicaltrials.gov . Unique identifier: NCT02641431.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Nagase, S., Kusano, K. F., Morita, H., Nishii, N., Banba, K., Watanabe, A., Hiramatsu, S., Nakamura, K., Sakuragi, S., & Ohe, T. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.059 · Cited by 75
Cited by
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Present Status of Brugada Syndrome
Brugada, J., Campuzano, O., Arbelo, E., Sarquella-Brugada, G., & Brugada, R. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.037 · Cited by 432
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Clinical Spectrum of SCN5A Mutations
Wilde, A. A. M., & Amin, A. S. (2018) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2018.03.006 · Cited by 342
Metadata
- Authors
- Pappone, C., Brugada, J., Vicedomini, G., Ciconte, G., Manguso, F., Saviano, M., Vitale, R., Cuko, A., Giannelli, L., Calovic, Z., Conti, M., Pozzi, P., Natalizia, A., Crisà, S., Borrelli, V., Brugada, R., Sarquella-Brugada, G., Guazzi, M., Frigiola, A., Menicanti, L., & Santinelli, V.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2017-05
- Volume
- 10
- Issue
- 5
- Pages
- e005053-e005053
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2613895821
- Cited by
- 243
- References
- 2
- FWCI
- 17.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical Substrate Elimination in 135 Consecutive Patients With Brugada Syndrome. https://app.cochat.ai/papers/10.1161/circep.117.005053
- The paper
- Pappone, C., Brugada, J., Vicedomini, G., Ciconte, G., Manguso, F., Saviano, M., Vitale, R., Cuko, A., Giannelli, L., Calovic, Z., Conti, M., Pozzi, P., Natalizia, A., Crisà, S., Borrelli, V., Brugada, R., Sarquella-Brugada, G., Guazzi, M., Frigiola, A., . . . Santinelli, V. (2017). Electrical Substrate Elimination in 135 Consecutive Patients With Brugada Syndrome. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.117.005053
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.