Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

His-Optimized Cardiac Resynchronization Therapy to Maximize Electrical Resynchronization: A Feasibility Study

Open access
Vijayaraman, Pugazhendhi, Herweg, Bengt, Ellenbogen, Kenneth A., Gajek, Jacek·2019·Circulation: Arrhythmia and Electrophysiology

Abstract

Background: Cardiac resynchronization therapy (CRT) is an established therapy for patients with cardiomyopathy, left bundle branch block, and heart failure. His bundle pacing (HBP) may also improve clinical outcomes by narrowing QRS duration. The QRS narrowing by HBP may not always be optimal. The aim of the study was to determine if CRT could be optimized by sequential HBP followed by left ventricular (LV) pacing (His-Optimized CRT [HOT-CRT]) to maximize electrical resynchronization. Methods: We attempted permanent HBP in 27 patients (left bundle branch block 17, intraventricular conduction defect 5, and right ventricular pacing 5) referred for CRT in addition to LV lead. HBP was followed by LV pacing at a delay equal to His-ventricular interval. QRS duration at baseline, during HBP, biventricular pacing, and HOT-CRT was measured. Echocardiographic parameters and New York Heart Association functional class were assessed at baseline and during follow-up. Results: HOT-CRT was successful in 25 of 27 patients (age 72±15 years, men 23, ischemic 21). QRS duration at baseline was 183±27 ms and significantly narrowed to 162±17 ms with biventricular pacing ( P =0.003), to 151±24 ms during HBP ( P <0.0001), and further to 120±16 ms during HOT-CRT ( P <0.0001). During a mean follow-up of 14±10 months, LV ejection fraction improved from 24±7% to 38±10% ( P <0.0001), and New York Heart Association functional class changed from 3.3 to 2.04. Twenty-one of 25 patients (84%) were clinical responders while 23 of 25 (92%) showed echocardiographic response. Conclusions: In this feasibility cohort, HOT-CRT resulted in improved electrical resynchronization. HOT-CRT may improve clinical and echocardiographic outcomes in advanced heart failure patients requiring CRT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.118.006934

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 183

Metadata

Authors
Vijayaraman, P., Herweg, B., Ellenbogen, K. A., & Gajek, J.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2019-02
Volume
12
Issue
2
Pages
e006934-e006934
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W2914753177
Cited by
183
References
2
FWCI
15.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: His-Optimized Cardiac Resynchronization Therapy to Maximize Electrical Resynchronization: A Feasibility Study. https://app.cochat.ai/papers/10.1161/circep.118.006934
The paper
Vijayaraman, P., Herweg, B., Ellenbogen, K. A., & Gajek, J. (2019). His-Optimized Cardiac Resynchronization Therapy to Maximize Electrical Resynchronization: A Feasibility Study. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.118.006934

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.