Outcomes of Atrial Fibrillation Ablation in Morbidly Obese Patients Following Bariatric Surgery Compared With a Nonobese Cohort
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: Morbid obesity is associated with unacceptable high recurrence rates following atrial fibrillation ablation. The role of risk-factor modification including weight loss and improved glycemic control in reducing arrhythmia recurrence following ablation has been highlighted in recent years. In this study, we compared arrhythmia recurrence rates in morbidly obese patients who underwent prior bariatric surgery (BS) with those of nonobese patients following atrial fibrillation ablation in addition to morbidly obese patients who did not undergo BS. Methods: This was a single-center observational cohort study. We matched 51 morbidly obese patients [body mass index ≥40 kg/m 2 ] who had undergone prior BS in a 2:1 manner with 102 nonobese patients and 102 morbidly obese patients without prior BS on the basis of age, sex, and timing of atrial fibrillation ablation. Our primary outcome of interest was arrhythmia recurrence. Results: From the time of BS to ablation, BS was associated with a significant reduction in body mass index (47.6±9.3 to 36.7±7; P <0.0001), glycated hemoglobin (6.7±1.5 to 5.8±0.6; P <0.0001), and systolic blood pressure (145±13 to 118±11; P <0.0001). During a mean follow-up of 29±13 months following ablation, recurrent arrhythmia occurred in 10/51 (20%) patients in the BS group compared with 25/102 (24.5%) patients in the nonobese group and 56 (55%) patients in the non-BS morbidly obese group ( P <0.0001). No procedural complications were observed in the BS group. Conclusions: Bariatric surgery is associated with a reduction in arrhythmia recurrence following atrial fibrillation ablation in morbidly obese patients to those of nonobese patients. Morbidly obese patients should be considered for BS before atrial fibrillation ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Bariatric Surgery versus Intensive Medical Therapy for Diabetes — 5-Year Outcomes
Schauer, P. R., Bhatt, D. L., Kirwan, J. P., Wolski, K., Aminian, A., Brethauer, S. A., Navaneethan, S. D., Singh, R. P., Pothier, C. E., Nissen, S. E., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1600869 · Cited by 2,934
Self-citationObesity and the risk of new-onset atrial fibrillation
Wang, T. J. (2004) · JAMA · doi:10.1001/jama.292.20.2471 · Cited by 1,427
Long-Term Effect of Goal-Directed Weight Management in an Atrial Fibrillation Cohort
Pathak, R. K., Middeldorp, M. E., Meredith, M., Mehta, A. B., Mahajan, R., Wong, C. X., Twomey, D., Elliott, A. D., Kalman, J. M., Abhayaratna, W. P., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.002 · Cited by 1,036
Pathak, R. K., Middeldorp, M. E., Lau, D. H., Mehta, A. B., Mahajan, R., Twomey, D., Alasady, M., Hanley, L., Antic, N. A., McEvoy, R. D., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.028 · Cited by 949
Peromaa-Haavisto, P., Tuomilehto, H., Kössi, J., Virtanen, J., Luostarinen, M., Pihlajamäki, J., Käkelä, P., & Victorzon, M. (2017) · Sleep Medicine · doi:10.1016/j.sleep.2016.12.017 · Cited by 89
Cited by
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Obesity and cardiovascular disease: An ESC clinical consensus statement
Koskinas, K. C., Van Craenenbroeck, E. M., Antoniades, C., Blüher, M., Gorter, T. M., Hanssen, H., Marx, N., McDonagh, T. A., Mingrone, G., Rosengren, A., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae508 · Cited by 313
Catheter ablation for atrial fibrillation: current indications and evolving technologies
Parameswaran, R., Al-Kaisey, A. M., & Kalman, J. M. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00451-x · Cited by 251
Metadata
- Authors
- Donnellan, E., Wazni, O., Kanj, M., Hussein, A., Baranowski, B., Lindsay, B., Aminian, A., Jaber, W., Schauer, P., & Saliba, W.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2019-10
- Volume
- 12
- Issue
- 10
- Pages
- e007598-e007598
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2981246746
- Cited by
- 74
- References
- 6
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.