CoChat

Development and Validation of a Clinical Predictive Model for Identifying Hypertrophic Cardiomyopathy Patients at Risk for Atrial Fibrillation: The HCM-AF Score

Open access
Carrick, Richard T., Maron, Martin S., Adler, Arnon, Wessler, Benjamin, Hoss, Sara, Chan, Raymond H., Sridharan, Aadhavi, Huang, Dou, Cooper, Craig, Drummond, Jennifer, Rakowski, Harry, Maron, Barry J., Rowin, Ethan J. · 2021 · Circulation: Arrhythmia and Electrophysiology
Cited by 80

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Atrial fibrillation (AF) is the most common sustained arrhythmia in hypertrophic cardiomyopathy (HCM), associated with impaired quality of life, risk for embolic stroke, and unpredictable onset. We sought to create a predictive model to identify risk for AF development in HCM. Methods: A cohort of 1900 patients with HCM followed for newly diagnosed AF in the Tufts HCM center was used for model development. A cohort of 387 patients from Toronto General Hospital was used for external validation. Data in the development cohort generated the HCM-AF score, a point score to predict AF probability at 2 and 5 years: left atrial dimension (+2 points per 6 mm increase), age at clinical evaluation (+3 points per 10-year increase), age at initial HCM diagnosis (−2 points per 10-year increase), and heart failure symptoms (+3 points if symptomatic). Results: The HCM-AF score stratifies risk as low (<1.0%/y; score ≤17), intermediate (1.0-2.0%/y; score 18 to 21), and high risk (>2.0%/y; score ≥22) for AF development for individual patients. Concordance of the HCM-AF score was 0.70 in the development cohort and 0.68 in the external validation cohort. In the development cohort, 17.2% of high-risk patients developed AF (rate 3.4%/y), while only 3.3% of low-risk patients developed AF (rate 0.7%/y) at 5 years ( P <0.001). Similarly, in the external validation cohort, 13.3% of high-risk patients developed AF (rate 2.7%/y), whereas only 1.1% of low-risk patients developed AF (rate 0.2%/y). The HCM-AF score provided greater predictive power for future AF risk than left atrial dimension alone (concordance of 0.58) and outperformed other non–HCM risk models. Conclusions: The HCM-AF score is a novel externally validated predictive tool to identify AF risk in HCM. This score can reliably stratify patients with HCM to risk of newly diagnosed AF and offers the opportunity to inform expectations regarding future clinical course.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circep.120.009796

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 80

Metadata

Authors
Carrick, R. T., Maron, M. S., Adler, A., Wessler, B., Hoss, S., Chan, R. H., Sridharan, A., Huang, D., Cooper, C., Drummond, J., Rakowski, H., Maron, B. J., & Rowin, E. J.
Venue
Circulation: Arrhythmia and Electrophysiology
Published
2021-06
Volume
14
Issue
6
Pages
e009796-e009796
ISSN
  • 1941-3084 (ISSN-L)
  • 1941-3149
OpenAlex
W3172594374
Cited by
80
References
4
FWCI
4.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.