Smartwatch Algorithm for Automated Detection of Atrial Fibrillation
Open accessAbstract
Background The Kardia Band (KB) is a novel technology that enables patients to record a rhythm strip using an Apple Watch (Apple, Cupertino, California). The band is paired with an app providing automated detection of atrial fibrillation (AF).Objectives The purpose of this study was to examine whether the KB could accurately differentiate sinus rhythm (SR) from AF compared with physician-interpreted 12-lead electrocardiograms (ECGs) and KB recordings.Methods Consecutive patients with AF presenting for cardioversion (CV) were enrolled. Patients underwent pre-CV ECG along with a KB recording. If CV was performed, a post-CV ECG was obtained along with a KB recording. The KB interpretations were compared to physician-reviewed ECGs. The KB recordings were reviewed by blinded electrophysiologists and compared to ECG interpretations. Sensitivity, specificity, and K coefficient were measured.Results A total of 100 patients were enrolled (age 68 ± 11 years). Eight patients did not undergo CV as they were found to be in SR. There were 169 simultaneous ECG and KB recordings. Fifty-seven were noninterpretable by the KB. Compared with ECG, the KB interpreted AF with 93% sensitivity, 84% specificity, and a K coefficient of 0.77. Physician interpretation of KB recordings demonstrated 99% sensitivity, 83% specificity, and a K coefficient of 0.83. Of the 57 noninterpretable KB recordings, interpreting electrophysiologists diagnosed AF with 100% sensitivity, 80% specificity, and a K coefficient of 0.74. Among 113 cases where KB and physician readings of the same recording were interpretable, agreement was excellent (K coefficient = 0.88).Conclusions The KB algorithm for AF detection supported by physician review can accurately differentiate AF from SR. This technology can help screen patients prior to elective CV and avoid unnecessary procedures.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Wearables were used in one study to confirm persistent atrial fibrillation before admission for cardioversion.
“Wearables were used in one study to confirm persistent AF before admission for cardioversion53”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [53]
KardiaBand coupled with the SmartRhythm 2.0 DNN showed a sensitivity of >97% for detecting AF episodes lasting ≥1 h.
“KardiaBand (AliveCor, USA), now commercially discontinued, coupled with the SmartRhythm 2.0 DNN was compared with implantable cardiac monitors in a study that collected >31,000 h of continuous heart rhythm data and showed a sensitivity of >97% for detecting AF episodes lasting ≥1 h (ref.53).”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [53]
KardiaBand experienced difficulty in interpreting up to 33.3% of recordings in another analysis.
“However, the KardiaBand experienced difficulty in interpreting up to 33.3% of recordings in another analysis53.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [53]
Poor signal quality and false alarms can lead to inappropriate interpretation, resulting in unnecessary medical referrals and testing.
“For example, poor signal quality and false alarms can lead to inappropriate interpretation, resulting in unnecessary medical referrals and testing.141”
From Artificial intelligence for detection of cardiovascular-related diseases from wearable devices: A systematic review and meta-analysis (2022) · cites this paper as [141]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H. G., Cigarroa, J. E., Cleveland, J. C., CONTI, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,119 · see citing works
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955 · see citing works
The Rise of Consumer Health Wearables: Promises and Barriers
Piwek, L., Ellis, D. A., Andrews, S., & Joinson, A. (2016) · PLoS Medicine · doi:10.1371/journal.pmed.1001953 · Cited by 1,298 · see citing works
Lowres, N., Neubeck, L., Salkeld, G., Krass, I., McLachlan, A. J., Redfern, J., Bennett, A. A., Briffa, T., Bauman, A., Martinez, C., et al. (2014) · Thrombosis and Haemostasis · doi:10.1160/th14-03-0231 · Cited by 458 · see citing works
Assessing the Direct Costs of Treating Nonvalvular Atrial Fibrillation in the United States
Coyne, K. S., Paramore, C., Grandy, S., Mercader, M. A., Reynolds, M. W., & ZIMETBAUM, P. J. (2006) · Value in Health · doi:10.1111/j.1524-4733.2006.00124.x · Cited by 422 · see citing works
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422 · see citing works
Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
GILLINOV, S., ETIWY, M., WANG, R., BLACKBURN, G., PHELAN, D., GILLINOV, A. M., HOUGHTALING, P., JAVADIKASGARI, H., & DESAI, M. Y. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001284 · Cited by 345 · see citing works
Tarakji, K. G., Wazni, O. M., Callahan, T. D., Kanj, M. H., Hakim, A. H., Wolski, K., Wilkoff, B. L., Saliba, W. I., & Lindsay, B. D. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.11.015 · Cited by 138 · see citing works
Self-citationA review of the cost of atrial fibrillation
Wodchis, W. P., Bhatia, R. S., Leblanc, K., Meshkat, N., & Morra, D. (2012) · Value in Health · doi:10.1016/j.jval.2011.09.009 · Cited by 109 · see citing works
Mittal, S., Rogers, J., Sarkar, S., Koehler, J. L., Warman, E. N., Tomson, T. T., & PASSMAN, R. S. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.05.010 · Cited by 93 · see citing works
Lee, R. J., & Mittal, S. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.009 · Cited by 65 · see citing works
Screening for Atrial Fibrillation Using a Smartphone: Is There an App for That?
Freedman, B. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.004000 · Cited by 32 · see citing works
PASSMAN, R. S., Rogers, J., Sarkar, S., Reiland, J., Reisfeld, E., Koehler, J. L., & Mittal, S. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.037 · Cited by 23 · see citing works
Cost-of-illness studies of atrial fibrillation: methodological considerations
Becker, C. (2014) · Expert Review of Pharmacoeconomics & Outcomes Research · doi:10.1586/14737167.2014.940904 · Cited by 13 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
January, C. T., Wann, L. S., Calkins, H., Chen, L. Y., Cigarroa, J. E., Cleveland, J. C., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., Furie, K. L., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000665 · Cited by 2,744 · see citing works
Smart wearable devices in cardiovascular care: Where we are and how to move forward
Bayoumy, K., Gaber, M., Elshafeey, A., Mhaimeed, O., Dineen, E. H., Marvel, F. A., Martin, S. S., Muse, E. D., Turakhia, M. P., Tarakji, K. G., et al. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00522-7 · Cited by 829 · see citing works
Self-citationMobile Photoplethysmographic Technology to Detect Atrial Fibrillation
Guo, Y., Wang, H., Zhang, H., Liu, T., Liang, Z., Xia, Y., Yan, L., Xing, Y., Shi, H., Li, S., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.08.019 · Cited by 489 · see citing works
Smartwatch Performance for the Detection and Quantification of Atrial Fibrillation
Wasserlauf, J., You, C., Patel, R., Valys, A., Albert, D., & Passman, R. (2019) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006834 · Cited by 245 · see citing works
The WATCH AF trial: SmartWATCHes for detection of atrial fibrillation
Dörr, M., Nohturfft, V., Brasier, N., Bosshard, E., Djurdjevic, A., Gross, S., Raichle, C. J., Rhinisperger, M., Stöckli, R., & Eckstein, J. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.10.006 · Cited by 245 · see citing works
Clinical Validation of 5 Direct-to-Consumer Wearable Smart Devices to Detect Atrial Fibrillation
Mannhart, D., Lischer, M., Knecht, S., du Fay de Lavallaz, J., Strebel, I., Serban, T., Vögeli, D., Schaer, B., Osswald, S., Mueller, C., et al. (2023) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2022.09.011 · Cited by 175 · see citing works
Noseworthy, P. A., Kaufman, E. S., Chen, L. Y., Chung, M. K., Elkind, M. S. V., Joglar, J. A., Leal, M. A., McCabe, P. J., Pokorney, S. D., Yao, X., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000740 · Cited by 171 · see citing works
Serrano, L. P., Maita, K. C., Avila, F. R., Torres-Guzman, R. A., Garcia, J. P., Eldaly, A. S., Haider, C. R., Felton, C. L., Paulson, M. R., Maniaci, M. J., et al. (2023) · The Permanente Journal · doi:10.7812/tpp/23.022 · Cited by 162 · see citing works
Atrial fibrillation detection from wrist photoplethysmography signals using smartwatches
Bashar, S. K., Han, D., Hajeb-Mohammadalipour, S., Ding, E., Whitcomb, C., McManus, D. D., & Chon, K. H. (2019) · Scientific Reports · doi:10.1038/s41598-019-49092-2 · Cited by 120 · see citing works
Nielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98 · see citing works
Jensen, M. T., Treskes, R. W., Caiani, E. G., Casado-Arroyo, R., Cowie, M. R., Dilaveris, P., Duncker, D., Di Rienzo, M., Frederix, I., De Groot, N., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab011 · Cited by 93 · see citing works
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88 · see citing works
Mobile health applications for the detection of atrial fibrillation: a systematic review
Lopez Perales, C. R., Van Spall, H. G. C., Maeda, S., Jimenez, A., Laţcu, D. G., Milman, A., Kirakoya-Samadoulougou, F., Mamas, M. A., Muser, D., & Casado Arroyo, R. (2021) · EP Europace · doi:10.1093/europace/euaa139 · Cited by 77 · see citing works
Fan, Y.-Y., Li, Y.-G., Li, J., Cheng, W.-K., Shan, Z.-L., Wang, Y.-T., & Guo, Y.-T. (2019) · JMIR mHealth and uHealth · doi:10.2196/11437 · Cited by 81 · see citing works
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74 · see citing works
How will machine learning inform the clinical care of atrial fibrillation?
Siontis, K. C., Yao, X., Pirruccello, J. P., Philippakis, A. A., & Noseworthy, P. A. (2020) · Circulation Research · doi:10.1161/circresaha.120.316401 · Cited by 61 · see citing works
Exercise testing and exercise rehabilitation for patients with atrial fibrillation
Keteyian, S. J., Ehrman, J. K., Fuller, B., & Pack, Q. R. (2019) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0000000000000423 · Cited by 60 · see citing works
Newer technologies for detection of atrial fibrillation
Zungsontiporn, N., & Link, M. S. (2018) · BMJ · doi:10.1136/bmj.k3946 · Cited by 53 · see citing works
Research on digital technology use in cardiology: bibliometric analysis
Yeung, A. W. K., Kulnik, S. T., Parvanov, E. D., Fassl, A., Eibensteiner, F., Völkl-Kernstock, S., Kletecka-Pulker, M., Crutzen, R., Gutenberg, J., Höppchen, I., et al. (2022) · Journal of Medical Internet Research · doi:10.2196/36086 · Cited by 44 · see citing works
- Authors
- Bumgarner, J. M., Lambert, C. T., Hussein, A. A., Cantillon, D. J., Baranowski, B., Wolski, K., Lindsay, B. D., Wazni, O. M., & Tarakji, K. G.
- Affiliations
- Cleveland Clinic (US)
- Corresponding author
- Tarakji, Khaldoun G.
- ORCID
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2018-05
- Volume
- 71
- Issue
- 21
- Pages
- 2381-2388
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2791889721
- Cited by
- 446
- References
- 14
- Citations by year
- 2026: 25 · 2025: 41 · 2024: 45 · 2023: 43 · 2022: 69 · 2021: 83 · 2020: 71 · 2019: 52 · 2018: 15
- FWCI
- 41.80
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of the American College of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- atrial fibrillation, automated detection, Apple Watch, smartwatches, electrocardiogram, sinus rhythm, cardioversion, physician review, diagnostic accuracy
- MeSH terms
- Wearable Electronic Devices, Aged, Aged, 80 and over, Algorithms, Atrial Fibrillation, Electric Countershock, Electrocardiography, Female, Humans, Male, Middle Aged, Prospective Studies, Single-Blind Method, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review