Characterization of Static and Dynamic Left Ventricular Diastolic Function in Patients With Heart Failure With a Preserved Ejection Fraction
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background—: Congestive heart failure in the setting of a preserved left ventricular (LV) ejection fraction is increasing in prevalence among the senior population. The underlying pathophysiologic abnormalities in ventricular function and structure remain unclear for this disorder. We hypothesized that patients with heart failure with preserved ejection fraction (HFPEF) would have marked abnormalities in LV diastolic function with increased static diastolic stiffness and slowed myocardial relaxation compared with age-matched healthy controls. Methods and Results—: Eleven highly screened patients (4 men, 7 women) aged 73±7 years with HFPEF were recruited to participate in this study. Thirteen sedentary healthy controls (7 men, 6 women) aged 70±4 years also were recruited. All subjects underwent pulmonary artery catheterization with measurement of cardiac output, end-diastolic volumes, and pulmonary capillary wedge pressures at baseline; cardiac unloading (lower-body negative pressure or upright tilt); and cardiac loading (rapid saline infusion). The data were used to define the Frank-Starling and LV end-diastolic pressure-volume relationships. Doppler echocardiographic data (tissue Doppler velocities, isovolumic relaxation time, propagation velocity of early mitral inflow , E/A-wave ratio) were obtained at each level of cardiac preload. Compared with healthy controls, patients with HFPEF had similar LV contractile function and static LV compliance but reduced LV chamber distensibility with elevated filling pressures and slower myocardial relaxation as assessed by tissue Doppler imaging. Conclusions—: In this small, highly screened patient population with hemodynamically confirmed HFPEF, increased end-diastolic static ventricular stiffness relative to age-matched controls was not a universal finding. Nevertheless, patients with HFPEF, even when well compensated, had elevated filling pressures, reduced distensibility, and increased diastolic wall stress compared with controls. In contrast, LV relaxation as assessed by tissue Doppler variables appeared consistently impaired in patients with HFPEF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The natural history of congestive heart failure: the Framingham study
McKee, P. A., Castelli, W. P., McNamara, P. M., & Kannel, W. B. (1971) · New England Journal of Medicine · doi:10.1056/nejm197112232852601 · Cited by 3,448
Effect of Aging and Physical Activity on Left Ventricular Compliance
Arbab-Zadeh, A., Dijk, E., Prasad, A., Fu, Q., Torres, P., Zhang, R., Thomas, J. D., Palmer, D., & Levine, B. D. (2004) · Circulation · doi:10.1161/01.cir.0000142863.71285.74 · Cited by 535
Self-citation
Cited by
2015 ESC/ERS Guidelines for the diagnosis and treatment of pulmonary hypertension
Galiè, N., Humbert, M., Vachiery, J.-L., Gibbs, S., Lang, I., Torbicki, A., Simonneau, G., Peacock, A., Vonk Noordegraaf, A., Beghetti, M., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv317 · Cited by 6,931
Galiè, N., Humbert, M., Vachiery, J.-L., Gibbs, S., Lang, I., Torbicki, A., Simonneau, G., Peacock, A., Vonk Noordegraaf, A., Beghetti, M., et al. (2015) · European Respiratory Journal · doi:10.1183/13993003.01032-2015 · Cited by 3,172
Fletcher, G. F., Ades, P. A., Kligfield, P., Arena, R., Balady, G. J., Bittner, V. A., Coke, L. A., Fleg, J. L., Forman, D. E., Gerber, T. C., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829b5b44 · Cited by 2,235
Definitions and Diagnosis of Pulmonary Hypertension
Hoeper, M. M., Bogaard, H. J., Condliffe, R., Frantz, R., Khanna, D., Kurzyna, M., Langleben, D., Manes, A., Satoh, T., Torres, F., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.032 · Cited by 1,766
Phenomapping for Novel Classification of Heart Failure With Preserved Ejection Fraction
Shah, S. J., Katz, D. H., Selvaraj, S., Burke, M. A., Yancy, C. W., Gheorghiade, M., Bonow, R. O., Huang, C.-C., & Deo, R. C. (2015) · Circulation · doi:10.1161/circulationaha.114.010637 · Cited by 1,157
“Atrial fibrillation 17 (13) 26 (22) 64 (43) <0.”
The pathophysiology of heart failure with preserved ejection fraction
Borlaug, B. A. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.83 · Cited by 726
2015 ESC/ERS Guidelines for the Diagnosis and Treatment of Pulmonary Hypertension
Galiè, N., Humbert, M., Vachiery, J.-L., Gibbs, S., Lang, I., Torbicki, A., Simonneau, G., Peacock, A., Noordegraaf, A. V., Beghetti, M., et al. (2016) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2016.01.002 · Cited by 357
Dose–Response Relationship Between Physical Activity and Risk of Heart Failure: A Meta-Analysis
Pandey, A., Garg, S., Khunger, M., Darden, D., Ayers, C., Kumbhani, D. J., Mayo, H. G., de Lemos, J. A., & Berry, J. D. (2015) · Circulation · doi:10.1161/circulationaha.115.015853 · Cited by 272
Abnormal Haemodynamic Response to Exercise in Heart Failure with Preserved Ejection Fraction
Bhella, P. S., Prasad, A., Heinicke, K., Hastings, J. L., Arbab-Zadeh, A., Adams-Huet, B., Pacini, E. L., Shibata, S., Palmer, M. D., Newcomer, B. R., et al. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfr133 · Cited by 238
“HFpEF patient co-morbidities and cardiac medications have been published previously.(14) Thirteen healthy, similarly aged, sedentary individuals with no major medical conditions served as controls.”
BackgroundMethodInfluentialSelf-citationHeart failure with preserved ejection fraction: a clinical dilemma
Komajda, M., & Lam, C. S. P. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu067 · Cited by 197
Exercise Training as Therapy for Heart Failure: Current Status and Future Directions
Fleg, J. L., Cooper, L. S., Borlaug, B. A., Haykowsky, M. J., Kraus, W. E., Levine, B. D., Pfeffer, M. A., Piña, I. L., Poole, D. C., Reeves, G. R., et al. (2015) · Circulation: Heart Failure · doi:10.1161/circheartfailure.113.001420 · Cited by 172
“Patients with HFpEF seem to have hearts that are less distensible than those of sedentary, age-matched controls, with increased wall stress, slower relaxation, and impaired ventriculo-arterial coupling.(19) These changes lead to markedly increased filling pressures during exercise, which likely contributes to dyspnea…”
Self-citationHeart Failure With Preserved Ejection Fraction
Reddy, Y. N. V., & Borlaug, B. A. (2016) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2015.12.002 · Cited by 159
Pandey, A., Patel, K. V., Bahnson, J. L., Gaussoin, S. A., Martin, C. K., Balasubramanyam, A., Johnson, K. C., McGuire, D. K., Bertoni, A. G., Kitzman, D., et al. (2020) · Circulation · doi:10.1161/circulationaha.119.044865 · Cited by 127
Lamberts, R. R., Lingam, S. J., Wang, H.-Y., Bollen, I. A., Hughes, G., Galvin, I. F., Bunton, R. W., Bahn, A., Katare, R., Baldi, J., et al. (2014) · Cardiovascular Diabetology · doi:10.1186/1475-2840-13-72 · Cited by 60
“More recently, patients with preserved EF showed a preserved static (intrinsic to the heart) Frank-Starling mechanism [31], whereas the beat-to-beat dynamic (including the heart-arterial interaction) Frank-Starling mechanism was impaired in these patients [32].”
BackgroundCarrick-Ranson, G., Howden, E. J., Brazile, T. L., Levine, B. D., & Reading, S. A. (2023) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00798.2022 · Cited by 23
Self-citation
Metadata
- Authors
- Prasad, A., Hastings, J. L., Shibata, S., Popovic, Z. B., Arbab-Zadeh, A., Bhella, P. S., Okazaki, K., Fu, Q., Berk, M., Palmer, D., Greenberg, N. L., Garcia, M. J., Thomas, J. D., & Levine, B. D.
- Venue
- Circulation: Heart Failure
- Published
- 2010-09
- Volume
- 3
- Issue
- 5
- Pages
- 617-626
- ISSN
- 1941-3289 (ISSN-L)
- 1941-3297
- OpenAlex
- W2162693762
- Cited by
- 112
- References
- 2
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.