CoChat

Percutaneous Left-Ventricular Support With the Impella-2.5–Assist Device in Acute Cardiogenic Shock: Results of the Impella–EUROSHOCK-Registry

Open access
Lauten, Alexander, Engström, Annemarie E., Jung, Christian, Empen, Klaus, Erne, Paul, Cook, Stéphane, Windecker, Stephan, Bergmann, Martin W., Klingenberg, Roland, Lüscher, Thomas F., Haude, Michael, Rulands, Dierk, Butter, Christian, Ullman, Bengt, Hellgren, Laila, Modena, Maria Grazia, Pedrazzini, Giovanni, Henriques, Jose P.S., Figulla, Hans R., Ferrari, Markus · 2013 · Circulation: Heart Failure
Cited by 328

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

Background—: Acute cardiogenic shock after myocardial infarction is associated with high in-hospital mortality attributable to persisting low-cardiac output. The Impella–EUROSHOCK-registry evaluates the safety and efficacy of the Impella-2.5–percutaneous left-ventricular assist device in patients with cardiogenic shock after acute myocardial infarction. Methods and Results—: This multicenter registry retrospectively included 120 patients (63.6±12.2 years; 81.7% male) with cardiogenic shock from acute myocardial infarction receiving temporary circulatory support with the Impella-2.5–percutaneous left-ventricular assist device. The primary end point evaluated mortality at 30 days. The secondary end point analyzed the change of plasma lactate after the institution of hemodynamic support, and the rate of early major adverse cardiac and cerebrovascular events as well as long-term survival. Thirty-day mortality was 64.2% in the study population. After Impella-2.5–percutaneous left-ventricular assist device implantation, lactate levels decreased from 5.8±5.0 mmol/L to 4.7±5.4 mmol/L ( P =0.28) and 2.5±2.6 mmol/L ( P =0.023) at 24 and 48 hours, respectively. Early major adverse cardiac and cerebrovascular events were reported in 18 (15%) patients. Major bleeding at the vascular access site, hemolysis, and pericardial tamponade occurred in 34 (28.6%), 9 (7.5%), and 2 (1.7%) patients, respectively. The parameters of age >65 and lactate level >3.8 mmol/L at admission were identified as predictors of 30-day mortality. After 317±526 days of follow-up, survival was 28.3%. Conclusions—: In patients with acute cardiogenic shock from acute myocardial infarction, Impella 2.5–treatment is feasible and results in a reduction of lactate levels, suggesting improved organ perfusion. However, 30-day mortality remains high in these patients. This likely reflects the last-resort character of Impella-2.5–application in selected patients with a poor hemodynamic profile and a greater imminent risk of death. Carefully conducted randomized controlled trials are necessary to evaluate the efficacy of Impella-2.5–support in this high-risk patient group.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circheartfailure.112.967224

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

Metadata

Authors
Lauten, A., Engström, A. E., Jung, C., Empen, K., Erne, P., Cook, S., Windecker, S., Bergmann, M. W., Klingenberg, R., Lüscher, T. F., Haude, M., Rulands, D., Butter, C., Ullman, B., Hellgren, L., Modena, M. G., Pedrazzini, G., Henriques, J. P. S., Figulla, H. R., & Ferrari, M.
Venue
Circulation: Heart Failure
Published
2013-01
Volume
6
Issue
1
Pages
23-30
ISSN
  • 1941-3289 (ISSN-L)
  • 1941-3297
OpenAlex
W2016482150
Cited by
328
References
30
FWCI
12.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.