Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Outcome and Complications After Implantable Cardioverter Defibrillator Therapy in Hypertrophic Cardiomyopathy: Systematic Review and Meta-Analysis

Schinkel, Arend F.L., Vriesendorp, Pieter A., Sijbrands, Eric J.G., Jordaens, Luc J.L.M., ten Cate, Folkert J., Michels, Michelle · 2012 · Circulation: Heart Failure

Abstract

Background—: Previous observational studies demonstrated that patients with hypertrophic cardiomyopathy at risk for sudden cardiac death (SCD) may benefit from implantable cardioverter defibrillator (ICD) therapy. A complete overview of outcome and complications after ICD therapy is currently not available. This study pools data from published studies on outcome and complications after ICD therapy in patients with hypertrophic cardiomyopathy. Methods and Results—: A PubMed database search returned 27 studies on 16 cohorts reporting outcome and complications after ICD therapy in patients with hypertrophic cardiomyopathy. In case of >1 publications on a particular cohort, the publication with the largest number of patients was included in the meta-analysis. ICD interventions, complications, and mortality rates were extracted, pooled, and analyzed. There were 2190 patients (mean age, 42 years; 38% women), most of whom (83%) received an ICD for primary prevention of SCD. Risk factors for SCD were left ventricular wall thickness ≥30 mm (20%), family history of SCD (43%), nonsustained ventricular tachycardia (46%), syncope (41%), and abnormal blood pressure response (25%). During the 3.7-year follow-up, the annualized cardiac mortality rate was 0.6%, the noncardiac mortality rate was 0.4%, and the appropriate ICD intervention rate was 3.3%. The annualized inappropriate ICD intervention rate was 4.8% and the annualized ICD-related complication rate was 3.4%. Conclusions—: This meta-analysis demonstrates a low cardiac and noncardiac mortality rate after ICD therapy in patients with hypertrophic cardiomyopathy. Appropriate ICD intervention occurred at a rate of 3.3%/year, thereby, most probably, preventing SCD. Inappropriate ICD intervention and complications are not uncommon.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circheartfailure.112.969626

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 169

Metadata

Authors
Schinkel, A. F. L., Vriesendorp, P. A., Sijbrands, E. J. G., Jordaens, L. J. L. M., ten Cate, F. J., & Michels, M.
Venue
Circulation: Heart Failure
Published
2012-09
Volume
5
Issue
5
Pages
552-559
ISSN
  • 1941-3289 (ISSN-L)
  • 1941-3297
OpenAlex
W2126498585
Cited by
169
References
3
FWCI
7.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Outcome and Complications After Implantable Cardioverter Defibrillator Therapy in Hypertrophic Cardiomyopathy: Systematic Review and Meta-Analysis. https://app.cochat.ai/papers/10.1161/circheartfailure.112.969626
The paper
Schinkel, A. F. L., Vriesendorp, P. A., Sijbrands, E. J. G., Jordaens, L. J. L. M., ten Cate, F. J., & Michels, M. (2012). Outcome and Complications After Implantable Cardioverter Defibrillator Therapy in Hypertrophic Cardiomyopathy: Systematic Review and Meta-Analysis. Circulation: Heart Failure. https://doi.org/10.1161/circheartfailure.112.969626

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.