Accuracy and Usability of a Self-Administered 6-Minute Walk Test Smartphone Application
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background—: The 6-minute walk test (6MWT) independently predicts congestive heart failure severity, death, and heart failure hospitalizations, but must be administered in clinic by qualified staff on a premeasured course. As part of the Health eHeart Study, we sought to develop and validate a self-administered 6MWT mobile application (SA-6MWTapp) for independent use at home by patients. Methods and Results—: We performed a validation study of an SA-6MWTapp in 103 participants. In phase 1 (n=52), we developed a distance-estimation algorithm for the SA-6MWTapp by comparing step counts from an Actigraph and measured distance on a premeasured 6MWT course with step counts and estimated distance obtained simultaneously from our SA-6MWTapp (best estimation algorithm, r=0.89 [95% confidence interval 0.78–0.99]). In phase 2, 32 participants (including those with congestive heart failure and pulmonary hypertension) used the SA-6MWTapp independently in clinic, and the distance estimated by the SA-6MWTapp was compared with the measured distance (r=0.83 [95% confidence interval 0.79–0.92]). In phase 3, 19 patients with congestive heart failure and pulmonary hypertension consecutively enrolled from clinic performed 3.2±1 SA-6MWTapp tests per week at home over 2 weeks. Distances estimated from the SA-6MWTapp during home 6MWTs were highly repeatable (coefficient of variation =4.6%) and correlated with in-clinic–measured distance (r=0.88 [95% confidence interval 0.87–0.89]). Usability surveys performed during the second (in-clinic) and third (at-home) phases demonstrated that the SA-6MWTapp was simple and easy to use independently. Conclusions—: An SA-6MWTapp is easy to use and yields accurate repeatable measurements in the clinic and at home.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ATS Statement: Guidelines for the Six-Minute Walk Test
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.166.1.at1102 · Cited by 11,195
O'Connor (2009) · doi:10.1001/jama.2009.454 · Cited by 2,173
Beatty, A. L., Schiller, N. B., & Whooley, M. A. (2012) · Archives of Internal Medicine · doi:10.1001/archinternmed.2012.2198 · Cited by 174 · cited 1×
“in the lowest quartile of 6MWT distance (<419 m) had a >4-fold increased hazard for major cardiovascular events as compared with those within the highest quartile (>544 m).(16) 6MWT distance is also an important end point in the assessment of the efficacy of drugs and devices.”
Ingle, L., Shelton, R. J., Rigby, A. S., Nabb, S., Clark, A. L., & Cleland, J. G. F. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi259 · Cited by 126
Vermeulen, J., Neyens, J., Spreeuwenberg, van Rossum, E., Sipers, Habets, Hewson, D., & de Witte (2013) · Patient Preference and Adherence · doi:10.2147/ppa.s45897 · Cited by 64
Cited by
Sim, I. (2019) · New England Journal of Medicine · doi:10.1056/nejmra1806949 · Cited by 491
McConnell, M. V., Shcherbina, A., Pavlovic, A., Homburger, J. R., Goldfeder, R. L., Waggot, D., Cho, M. K., Rosenberger, M. E., Haskell, W. L., Myers, J., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.4395 · Cited by 239
Grady, C., Cummings, S. R., Rowbotham, M. C., McConnell, M. V., Ashley, E. A., & Kang, G. (2017) · New England Journal of Medicine · doi:10.1056/nejmra1603773 · Cited by 213
Inan, O. T., Baran Pouyan, M., Javaid, A. Q., Dowling, S., Etemadi, M., Dorier, A., Heller, J. A., Bicen, A. O., Roy, S., De Marco, T., et al. (2018) · Circulation: Heart Failure · doi:10.1161/circheartfailure.117.004313 · Cited by 207
Application of mobile health, telemedicine and artificial intelligence to echocardiography
Seetharam, K., Kagiyama, N., & Sengupta, P. P. (2019) · Echo Research & Practice · doi:10.1530/erp-18-0081 · Cited by 111
Metadata
- Authors
- Brooks, G. C., Vittinghoff, E., Iyer, S., Tandon, D., Kuhar, P., Madsen, K. A., Marcus, G. M., Pletcher, M. J., & Olgin, J. E.
- Venue
- Circulation: Heart Failure
- Published
- 2015-09
- Volume
- 8
- Issue
- 5
- Pages
- 905-913
- ISSN
- 1941-3289 (ISSN-L)
- 1941-3297
- OpenAlex
- W2156441323
- Cited by
- 108
- References
- 5
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy and Usability of a Self-Administered 6-Minute Walk Test Smartphone Application. https://app.cochat.ai/papers/10.1161/circheartfailure.115.002062
- The paper
- Brooks, G. C., Vittinghoff, E., Iyer, S., Tandon, D., Kuhar, P., Madsen, K. A., Marcus, G. M., Pletcher, M. J., & Olgin, J. E. (2015). Accuracy and Usability of a Self-Administered 6-Minute Walk Test Smartphone Application. Circulation: Heart Failure. https://doi.org/10.1161/circheartfailure.115.002062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.