Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Rapid and Highly Accurate Prediction of Poor Loop Diuretic Natriuretic Response in Patients With Heart Failure

Open access
Testani, Jeffrey M., Hanberg, Jennifer S., Cheng, Susan, Rao, Veena, Onyebeke, Chukwuma, Laur, Olga, Kula, Alexander, Chen, Michael, Wilson, F. Perry, Darlington, Andrew, Bellumkonda, Lavanya, Jacoby, Daniel, Tang, W.H. Wilson, Parikh, Chirag R.·2016·Circulation: Heart Failure

Abstract

Background—: Removal of excess sodium and fluid is a primary therapeutic objective in acute decompensated heart failure and commonly monitored with fluid balance and weight loss. However, these parameters are frequently inaccurate or not collected and require a delay of several hours after diuretic administration before they are available. Accessible tools for rapid and accurate prediction of diuretic response are needed. Methods and Results—: Based on well-established renal physiological principles, an equation was derived to predict net sodium output using a spot urine sample obtained 1 or 2 hours after loop diuretic administration. This equation was then prospectively validated in 50 acute decompensated heart failure patients using meticulously obtained timed 6-hour urine collections to quantify loop diuretic-induced cumulative sodium output. Poor natriuretic response was defined as a cumulative sodium output of <50 mmol, a threshold that would result in a positive sodium balance with twice-daily diuretic dosing. Following a median dose of 3 mg (2–4 mg) of intravenous bumetanide, 40% of the population had a poor natriuretic response. The correlation between measured and predicted sodium output was excellent ( r =0.91; P <0.0001). Poor natriuretic response could be accurately predicted with the sodium prediction equation (area under the curve =0.95, 95% confidence interval 0.89–1.0; P <0.0001). Clinically recorded net fluid output had a weaker correlation ( r =0.66; P <0.001) and lesser ability to predict poor natriuretic response (area under the curve =0.76, 95% confidence interval 0.63–0.89; P =0.002). Conclusions—: In patients being treated for acute decompensated heart failure, poor natriuretic response can be predicted soon after diuretic administration with excellent accuracy using a spot urine sample.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circheartfailure.115.002370

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 177

Metadata

Authors
Testani, J. M., Hanberg, J. S., Cheng, S., Rao, V., Onyebeke, C., Laur, O., Kula, A., Chen, M., Wilson, F. P., Darlington, A., Bellumkonda, L., Jacoby, D., Tang, W. H. W., & Parikh, C. R.
Venue
Circulation: Heart Failure
Published
2016-01
Volume
9
Issue
1
Pages
e002370-e002370
ISSN
  • 1941-3289 (ISSN-L)
  • 1941-3297
OpenAlex
W2219693025
Cited by
177
References
4
FWCI
4.24
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid and Highly Accurate Prediction of Poor Loop Diuretic Natriuretic Response in Patients With Heart Failure. https://app.cochat.ai/papers/10.1161/circheartfailure.115.002370
The paper
Testani, J. M., Hanberg, J. S., Cheng, S., Rao, V., Onyebeke, C., Laur, O., Kula, A., Chen, M., Wilson, F. P., Darlington, A., Bellumkonda, L., Jacoby, D., Tang, W. H. W., & Parikh, C. R. (2016). Rapid and Highly Accurate Prediction of Poor Loop Diuretic Natriuretic Response in Patients With Heart Failure. Circulation: Heart Failure. https://doi.org/10.1161/circheartfailure.115.002370

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.