Prospective Comparison of Valve Regurgitation Quantitation by Cardiac Magnetic Resonance Imaging and Transthoracic Echocardiography

Cawley, Peter J., Hamilton-Craig, Christian, Owens, David S., Krieger, Eric V., Strugnell, Wendy E., Mitsumori, Lee, D’Jang, Caryn L., Schwaegler, Rebecca G., Nguyen, Khanh Q., Nguyen, Bianca, Maki, Jeffrey H., Otto, Catherine M.·2013·Circulation: Cardiovascular Imaging

Abstract

Background—: Both transthoracic echocardiography (TTE) and cardiac magnetic resonance (CMR) imaging allow quantification of chronic aortic regurgitation (AR) and mitral regurgitation (MR). We hypothesized that CMR measurement of regurgitant volume (RVol) is more reproducible than TTE. Methods and Results—: TTE and CMR performed on the same day in 57 prospectively enrolled adults (31 with AR, 26 with MR) were measured by 2 independent physicians. TTE RVol AR was calculated as Doppler left ventricular outflow minus inflow stroke volume. RVol MR was calculated by both the proximal isovelocity surface area method and Doppler volume flow at 2 sites. CMR RVol AR was calculated by phase-contrast velocity mapping at the aortic sinuses and RVol MR as total left ventricular minus forward stroke volume. Intraobserver and interobserver variabilities were similar. For AR, the Bland–Altman mean interobserver difference in RVol was −0.7 mL (95% confidence interval [CI], −5 to 4) for CMR and −9 mL (95% CI, −53 to −36) for TTE. The Pearson correlation was higher ( P =0.001) between CMR (0.99) than TTE readers (0.89). For MR, the Bland–Altman mean difference in RVol between observers was −4 mL (95% CI, −21 to 13) for CMR compared with 0.7 mL (95% CI, −30 to 32) for the proximal isovelocity surface area and −10 mL (95% CI, −76 to 56) for TTE volume flow at 2 sites. Correlation was similar for CMR (0.94) versus TTE readers (0.90 for the proximal isovelocity surface area). Conclusions—: Compared with TTE, CMR has lower intraobserver and interobserver variabilities for RVol AR , suggesting CMR may be superior for serial measurements. Although RVol MR is similar by TTE and CMR, variability in measured RVol by both approaches suggests that caution is needed in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.112.975623

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 270

Metadata

Authors
Cawley, P. J., Hamilton-Craig, C., Owens, D. S., Krieger, E. V., Strugnell, W. E., Mitsumori, L., D’Jang, C. L., Schwaegler, R. G., Nguyen, K. Q., Nguyen, B., Maki, J. H., & Otto, C. M.
Venue
Circulation: Cardiovascular Imaging
Published
2013-01
Volume
6
Issue
1
Pages
48-57
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2546457908
Cited by
270
References
21
FWCI
9.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prospective Comparison of Valve Regurgitation Quantitation by Cardiac Magnetic Resonance Imaging and Transthoracic Echocardiography. https://app.cochat.ai/papers/10.1161/circimaging.112.975623
The paper
Cawley, P. J., Hamilton-Craig, C., Owens, D. S., Krieger, E. V., Strugnell, W. E., Mitsumori, L., D’Jang, C. L., Schwaegler, R. G., Nguyen, K. Q., Nguyen, B., Maki, J. H., & Otto, C. M. (2013). Prospective Comparison of Valve Regurgitation Quantitation by Cardiac Magnetic Resonance Imaging and Transthoracic Echocardiography. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.112.975623

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.