Myocardial Tissue Characterization Using Magnetic Resonance Noncontrast T1 Mapping in Hypertrophic and Dilated Cardiomyopathy

Open access
Dass, Sairia, Suttie, Joseph J., Piechnik, Stefan K., Ferreira, Vanessa M., Holloway, Cameron J., Banerjee, Rajarshi, Mahmod, Masliza, Cochlin, Lowri, Karamitsos, Theodoros D., Robson, Matthew D., Watkins, Hugh, Neubauer, Stefan·2012·Circulation: Cardiovascular Imaging

Abstract

Background—: Noncontrast magnetic resonance T1 mapping reflects a composite of both intra- and extracellular signal. We hypothesized that noncontrast T1 mapping can characterize the myocardium beyond that achieved by the well-established late gadolinium enhancement (LGE) technique (which detects focal fibrosis) in both hypertrophic (HCM) and dilated (DCM) cardiomyopathy, by detecting both diffuse and focal fibrosis. Methods and Results—: Subjects underwent Cardiovascular Magnetic Resonance imaging at 3T (28 HCM, 18 DCM, and 12 normals). Matching short-axis slices were acquired for cine, T1 mapping, and LGE imaging (0.1 mmol/kg). Circumferential strain was measured in the midventricular slice, and 31 P magnetic resonance spectroscopy was acquired for the septum of the midventricular slice. Mean T1 relaxation time was increased in HCM and DCM (HCM 1209±28 ms, DCM 1225±42 ms, normal 1178±13 ms, P <0.05). There was a weak correlation between mean T1 and LGE ( r =0.32, P <0.001). T1 values were higher in segments with LGE than in those without (HCM with LGE 1228±41 ms versus no LGE 1192±79 ms, P <0.01; DCM with LGE 1254±73 ms versus no LGE 1217±52 ms, P <0.01). However, in both HCM and DCM, even in segments unaffected by LGE, T1 values were significantly higher than normal ( P <0.01). T1 values correlated with disease severity, being increased as wall thickness increased in HCM; conversely, in DCM, T1 values were highest in the thinnest myocardial segments. T1 values also correlated significantly with circumferential strain ( r =0.42, P <0.01). Interestingly, this correlation remained statistically significant even for the slices without LGE ( r =0.56, P =0.04). Finally, there was also a statistically significant negative correlation between T1 values and phosphocreatine/adenosine triphosphate ratios ( r =−0.59, P <0.0001). Conclusions—: In HCM and DCM, noncontrast T1 mapping detects underlying disease processes beyond those assessed by LGE in relatively low-risk individuals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.112.976738

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 348

Metadata

Authors
Dass, S., Suttie, J. J., Piechnik, S. K., Ferreira, V. M., Holloway, C. J., Banerjee, R., Mahmod, M., Cochlin, L., Karamitsos, T. D., Robson, M. D., Watkins, H., & Neubauer, S.
Venue
Circulation: Cardiovascular Imaging
Published
2012-11
Volume
5
Issue
6
Pages
726-733
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2123860598
Cited by
348
References
34
FWCI
18.61
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Myocardial Tissue Characterization Using Magnetic Resonance Noncontrast T1 Mapping in Hypertrophic and Dilated Cardiomyopathy. https://app.cochat.ai/papers/10.1161/circimaging.112.976738
The paper
Dass, S., Suttie, J. J., Piechnik, S. K., Ferreira, V. M., Holloway, C. J., Banerjee, R., Mahmod, M., Cochlin, L., Karamitsos, T. D., Robson, M. D., Watkins, H., & Neubauer, S. (2012). Myocardial Tissue Characterization Using Magnetic Resonance Noncontrast T1 Mapping in Hypertrophic and Dilated Cardiomyopathy. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.112.976738

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.