Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Cardiac Magnetic Resonance Postcontrast T1 Time Is Associated With Outcome in Patients With Heart Failure and Preserved Ejection Fraction

Mascherbauer, Julia, Marzluf, Beatrice A., Tufaro, Caroline, Pfaffenberger, Stefan, Graf, Alexandra, Wexberg, Paul, Panzenböck, Adelheid, Jakowitsch, Johannes, Bangert, Christine, Laimer, Daniela, Schreiber, Catharina, Karakus, Gültekin, Hülsmann, Martin, Pacher, Richard, Lang, Irene M., Maurer, Gerald, Bonderman, Diana·2013·Circulation: Cardiovascular Imaging

Abstract

Background—: The underlying pathophysiology of heart failure with preserved ejection fraction (HFPEF) is incompletely understood, but myocardial extracellular matrix accumulation is thought to play a major role. Our aims were to estimate myocardial extracellular matrix using cardiac magnetic resonance T1 mapping and to assess the relationship between pathobiology/pathophysiology and prognosis. Methods and Results—: Patients with suspected HFPEF (n=100) were enrolled in this prospective, observational study. Confirmatory diagnostic tests, cardiac magnetic resonance imaging including T1 mapping, and invasive hemodynamic assessments were performed at baseline. Sixty-one patients with confirmed HFPEF entered a longitudinal outcome-monitoring phase (mean, 22.9±5.0 months), during which 16 had a cardiac event. Cardiac magnetic resonance T1 time (hazard ratio, 0.99; 95% confidence interval, 0.98–0.99; P =0.046), left atrial area (hazard ratio, 1.08; 95% confidence interval, 1.03–1.13; P <0.01), and pulmonary vascular resistance (hazard ratio, 1.01; 95% confidence interval, 1.00–1.01; P =0.03) were significantly associated with cardiac events. Patients with T1 times below the median (<388.3 ms) were at greater risk of cardiac events than the rest of the group ( P <0.01). Extracellular matrix of left ventricular biopsies (n=9), quantified by TissueFAXS technology correlated with T1 time ( R =0.98; P <0.01). T1 time also correlated with right ventricular–pulmonary arterial coupling (pulmonary vascular resistance: R =−0.36; P <0.01; right ventricular ejection fraction: R =0.28; P =0.01). Conclusions—: In the present preliminary study, cardiac magnetic resonance postcontrast T1 time is associated with prognosis in HFPEF, suggesting postcontrast T1 as possible biomarker for HFPEF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.113.000633

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 177

Metadata

Authors
Mascherbauer, J., Marzluf, B. A., Tufaro, C., Pfaffenberger, S., Graf, A., Wexberg, P., Panzenböck, A., Jakowitsch, J., Bangert, C., Laimer, D., Schreiber, C., Karakus, G., Hülsmann, M., Pacher, R., Lang, I. M., Maurer, G., & Bonderman, D.
Venue
Circulation: Cardiovascular Imaging
Published
2013-11
Volume
6
Issue
6
Pages
1056-1065
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2115204628
Cited by
177
References
5
FWCI
12.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Magnetic Resonance Postcontrast T1 Time Is Associated With Outcome in Patients With Heart Failure and Preserved Ejection Fraction. https://app.cochat.ai/papers/10.1161/circimaging.113.000633
The paper
Mascherbauer, J., Marzluf, B. A., Tufaro, C., Pfaffenberger, S., Graf, A., Wexberg, P., Panzenböck, A., Jakowitsch, J., Bangert, C., Laimer, D., Schreiber, C., Karakus, G., Hülsmann, M., Pacher, R., Lang, I. M., Maurer, G., & Bonderman, D. (2013). Cardiac Magnetic Resonance Postcontrast T1 Time Is Associated With Outcome in Patients With Heart Failure and Preserved Ejection Fraction. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.113.000633

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.