CoChat

Mechanistic Insights and Characterization of Sickle Cell Disease–Associated Cardiomyopathy

Open access
Desai, Ankit A., Patel, Amit R., Ahmad, Homaa, Groth, John V., Thiruvoipati, Thejasvi, Turner, Kristen, Yodwut, Chattanong, Czobor, Peter, Artz, Nicole, Machado, Roberto F., Garcia, Joe G.N., Lang, Roberto M. · 2014 · Circulation: Cardiovascular Imaging
Cited by 65

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background—: Cardiovascular disease is an important cause of morbidity and mortality in sickle cell disease (SCD). We sought to characterize sickle cell cardiomyopathy using multimodality noninvasive cardiovascular testing and identify potential causative mechanisms. Methods and Results—: Stable adults with SCD (n=38) and healthy controls (n=13) prospectively underwent same day multiparametric cardiovascular magnetic resonance (cine, T2* iron, vasodilator first pass myocardial perfusion, and late gadolinium enhancement imaging), transthoracic echocardiography, and applanation tonometry. Compared with controls, patients with SCD had severe dilation of the left ventricle (124±27 vs 79±12 mL/m 2 ), right ventricle (127±28 vs 83±14 mL/m 2 ), left atrium (65±16 vs 41±9 mL/m 2 ), and right atrium (78±17 vs 56±17 mL/m 2 ; P <0.01 for all). Patients with SCD also had a 21% lower myocardial perfusion reserve index than control subjects (1.47±0.34 vs 1.87±0.37; P =0.034). A significant subset of patients with SCD (25%) had evidence of late gadolinium enhancement, whereas only 1 patient had evidence of myocardial iron overload. Diastolic dysfunction was present in 26% of patients with SCD compared with 8% in controls. Estimated filling pressures (E/e′, 9.3±2.7 vs 7.3±2.0; P =0.0288) were higher in patients with SCD. Left ventricular dilation and the presence of late gadolinium enhancement were inversely correlated to hepatic T2* times (ie, hepatic iron overload because of frequent blood transfusions; P <0.05 for both), whereas diastolic dysfunction and increased filling pressures were correlated to aortic stiffness (augmentation pressure and index, P <0.05 for all). Conclusions—: Sickle cell cardiomyopathy is characterized by 4-chamber dilation and in some patients myocardial fibrosis, abnormal perfusion reserve, diastolic dysfunction, and only rarely myocardial iron overload. Left ventricular dilation and myocardial fibrosis are associated with increased blood transfusion requirements, whereas left ventricular diastolic dysfunction is predominantly correlated with increased aortic stiffness. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01044901.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.113.001420

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Desai, A. A., Patel, A. R., Ahmad, H., Groth, J. V., Thiruvoipati, T., Turner, K., Yodwut, C., Czobor, P., Artz, N., Machado, R. F., Garcia, J. G. N., & Lang, R. M.
Venue
Circulation: Cardiovascular Imaging
Published
2014-05
Volume
7
Issue
3
Pages
430-437
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2061292468
Cited by
65
References
6
FWCI
3.15
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.