Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record.

Replicating Patient-Specific Severe Aortic Valve Stenosis With Functional 3D Modeling

Maragiannis, Dimitrios, Jackson, Matthew S., Igo, Stephen R., Schutt, Robert C., Connell, Patrick, Grande-Allen, Jane, Barker, Colin M., Chang, Su Min, Reardon, Michael J., Zoghbi, William A., Little, Stephen H. · 2015 · Circulation: Cardiovascular Imaging

Abstract

Background—: 3D stereolithographic printing can be used to convert high-resolution computed tomography images into life-size physical models. We sought to apply 3D printing technologies to develop patient-specific models of the anatomic and functional characteristics of severe aortic valve stenosis. Methods and Results—: Eight patient-specific models of severe aortic stenosis (6 tricuspid and 2 bicuspid) were created using dual-material fused 3D printing. Tissue types were identified and segmented from clinical computed tomography image data. A rigid material was used for printing calcific regions, and a rubber-like material was used for soft tissue structures of the outflow tract, aortic root, and noncalcified valve cusps. Each model was evaluated for its geometric valve orifice area, echocardiographic image quality, and aortic stenosis severity by Doppler and Gorlin methods under 7 different in vitro stroke volume conditions. Fused multimaterial 3D printed models replicated the focal calcific structures of aortic stenosis. Doppler-derived measures of peak and mean transvalvular gradient correlated well with reference standard pressure catheters across a range of flow conditions ( r =0.988 and r =0.978 respectively, P <0.001). Aortic valve orifice area by Gorlin and Doppler methods correlated well ( r =0.985, P <0.001). Calculated aortic valve area increased a small amount for both methods with increasing flow ( P =0.002). Conclusions—: By combing the technologies of high-spatial resolution computed tomography, computer-aided design software, and fused dual-material 3D printing, we demonstrate that patient-specific models can replicate both the anatomic and functional properties of severe degenerative aortic valve stenosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.115.003626

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
Maragiannis, D., Jackson, M. S., Igo, S. R., Schutt, R. C., Connell, P., Grande-Allen, J., Barker, C. M., Chang, S. M., Reardon, M. J., Zoghbi, W. A., & Little, S. H.
Venue
Circulation: Cardiovascular Imaging
Published
2015-10
Volume
8
Issue
10
Pages
e003626-e003626
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2178617770
Cited by
163
References
0
FWCI
9.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Replicating Patient-Specific Severe Aortic Valve Stenosis With Functional 3D Modeling. https://app.cochat.ai/papers/10.1161/circimaging.115.003626
The paper
Maragiannis, D., Jackson, M. S., Igo, S. R., Schutt, R. C., Connell, P., Grande-Allen, J., Barker, C. M., Chang, S. M., Reardon, M. J., Zoghbi, W. A., & Little, S. H. (2015). Replicating Patient-Specific Severe Aortic Valve Stenosis With Functional 3D Modeling. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.115.003626

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.