Background—: Cardiovascular magnetic resonance based on the Lake Louise Criteria is used to make the diagnosis of acute myocarditis. Novel quantitative parametric mapping techniques promise to overcome some of its limitations. We aimed to evaluate quantitative cardiovascular magnetic resonance to detect and monitor acute myocarditis. Methods and Results—: Eighteen patients with clinical diagnosis of acute myocarditis (25 years [23–38 years]; 78% males) were prospectively enrolled and repeatedly underwent cardiovascular magnetic resonance at 1.5 T seven days (5–10 days) after symptom onset (FU0), after 5 weeks (FU1), and after 6 months (FU2). Eighteen age- and sex-matched healthy subjects served as controls. Cardiovascular magnetic resonance included imaging of edema, hyperemia, necrosis, and fibrosis using semiquantitative T2-weighted spin echo, T2 mapping, and T1 mapping before and 3 and 10 minutes after gadobutrol administration. Extracellular volume for diffuse and late gadolinium enhancement for focal fibrosis were assessed. Compared with controls, patients had significantly higher global T2 times at FU0 (55.1 ms [53.3–57.2 ms] versus 50.2 ms [49.2–52.0 ms]; P <0.001) and at FU1 (52.0 ms [52.0–53.2 ms]; P =0.007), which normalized at FU2 (50.9 ms [49.6–53.3 ms]; P =0.323). Global native T1 times in patients were elevated acutely (1004 ms [988–1048 ms] versus 975 ms [957–1004 ms]; P =0.002) and remained elevated throughout the follow-up (FU1: 998 ms [990–1027 ms]; P =0.014; FU2: 1000 ms [972–1027 ms]; P =0.044). Global extracellular volume fraction was statistically not different between patients and controls ( P =0.057). 77.8% (14/18) of patients had focal late gadolinium enhancement. T2 ratio was significantly elevated in patients with myocarditis at FU0 (2.2 [2.0–2.3] versus 1.6 [1.5–1.7]; P <0.001). The difference decreased during follow-up (FU1: 1.9 [1.7–1.9]; P =0.001 and FU2: 1.7 [1.7–1.8]; P =0.053). The diagnostic accuracy to discriminate between patients with acute myocarditis and healthy controls was 86% for T2>52 ms, 78% for native T1>981 ms, 74% for extracellular volume fraction >0.24, and 100% for T2 ratio >1.9. Conclusions—: Although both T2 and T1 mapping reliably detected acute myocarditis, only T2 mapping discriminated between acute and healed stages, underlining the incremental value of T2 mapping.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.116.005242

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 133

Metadata

Authors
von Knobelsdorff-Brenkenhoff, F., Schüler, J., Dogangüzel, S., Dieringer, M. A., Rudolph, A., Greiser, A., Kellman, P., & Schulz-Menger, J.
Venue
Circulation: Cardiovascular Imaging
Published
2017-02
Volume
10
Issue
2
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2588650203
Cited by
133
References
2
FWCI
8.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection and Monitoring of Acute Myocarditis Applying Quantitative Cardiovascular Magnetic Resonance. https://app.cochat.ai/papers/10.1161/circimaging.116.005242
The paper
von Knobelsdorff-Brenkenhoff, F., Schüler, J., Dogangüzel, S., Dieringer, M. A., Rudolph, A., Greiser, A., Kellman, P., & Schulz-Menger, J. (2017). Detection and Monitoring of Acute Myocarditis Applying Quantitative Cardiovascular Magnetic Resonance. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.116.005242

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.