Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 191

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Prognostic Value of Right Ventricular Ejection Fraction Assessed by Transthoracic 3D Echocardiography

Open access
Nagata, Yasufumi, Wu, Victor Chien-Chia, Kado, Yuichiro, Otani, Kyoko, Lin, Fen-Chiung, Otsuji, Yutaka, Negishi, Kazuaki, Takeuchi, Masaaki · 2017 · Circulation: Cardiovascular Imaging

Abstract

Background—: Cardiac magnetic resonance is the gold standard for the evaluation of right ventricular (RV) volumes, but it is impractical to perform in every patient. Although reference values of RV volumes and RV ejection fraction by 3D transthoracic echocardiography (3DTTE) have been established, their prognostic values have not been elucidated yet. We hypothesized that RV ejection fraction measured by 3DTTE (3DRVEF) predicts future cardiovascular events. Methods and Results—: In protocol 1, we determined the accuracy of RV volumes and RV ejection fraction measurements by 3DTTE against cardiac magnetic resonance in 60 subjects. In protocol 2, 3DRVEF was measured in 446 patients with various cardiovascular diseases. Study subjects were followed up to record cardiac death and major adverse cardiovascular events. In protocol 1, 3DTTE-determined RV end-diastolic volume, end-systolic volume, and RV ejection fraction had good correlations to those by cardiac magnetic resonance ( r =0.74–0.90). In protocol 2, 38 cardiac deaths and 88 major adverse cardiovascular events occurred during a median follow-up of 4.1 years. Univariable Cox proportional analysis revealed that 3DRVEF was associated with both cardiac death ( P <0.0001) and major adverse cardiovascular event ( P <0.0001). 3DRVEF remained as an independent predictor for cardiac death ( P <0.0001) and major adverse cardiovascular event ( P <0.0001) even in a stepwise multivariable Cox proportional hazard analysis. Classification and regression-tree analysis demonstrated that 3DRVEF played an important role for risk stratification. Conclusions—: 3DTTE-determined RV ejection fraction was independently associated with cardiac outcomes in patients with diverse backgrounds. 3DRVEF offered incremental value over clinical risk factors and the other echocardiographic parameters including left ventricular systolic and diastolic function for predicting future adverse outcome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.116.005384

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 191

Metadata

Authors
Nagata, Y., Wu, V. C.-C., Kado, Y., Otani, K., Lin, F.-C., Otsuji, Y., Negishi, K., & Takeuchi, M.
Venue
Circulation: Cardiovascular Imaging
Published
2017-02
Volume
10
Issue
2
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2587456882
Cited by
191
References
4
FWCI
13.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prognostic Value of Right Ventricular Ejection Fraction Assessed by Transthoracic 3D Echocardiography. https://app.cochat.ai/papers/10.1161/circimaging.116.005384
The paper
Nagata, Y., Wu, V. C.-C., Kado, Y., Otani, K., Lin, F.-C., Otsuji, Y., Negishi, K., & Takeuchi, M. (2017). Prognostic Value of Right Ventricular Ejection Fraction Assessed by Transthoracic 3D Echocardiography. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.116.005384

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.