CoChat

Melody Valve Implant Within Failed Bioprosthetic Valves in the Pulmonary Position: A Multicenter Experience

Gillespie, Matthew J., Rome, Jonathan J., Levi, Daniel S., Williams, Ryan J., Rhodes, John F., Cheatham, John P., Hellenbrand, William E., Jones, Thomas K., Vincent, Julie A., Zahn, Evan M., McElhinney, Doff B. · 2012 · Circulation: Cardiovascular Interventions
Cited by 164

The DOI matches its Crossref record.

Abstract

Background—: Transcatheter pulmonary valve implantation using the Melody valve has emerged as an important therapy for the treatment of postoperative right ventricular outflow tract dysfunction. Melody-in-bioprosthetic valves (BPV) is currently considered an off-label indication. We review the combined experience with transcatheter pulmonary valve implantation within BPVs from 8 centers in the United States and discuss technical aspects of the Melody-in-BPV procedure. Methods and Results—: A total of 104 patients underwent Melody-in-BPV in the pulmonary position at 8 US centers from April 2007 to January 2012. Ten different types of BPVs were intervened on, with Melody valve implantation at the intended site in all patients. Following Melody valve implant, the peak right ventricle-to-pulmonary artery gradient decreased from 38.7±16.3 to 10.9±6.7 mm Hg ( P <0.001), and the right ventricular systolic pressure fell from 71.6±21.7 to 46.7±15.9 mm Hg ( P <0.001). There was no serious procedural morbidity, and no deaths related to the catheterization or implant. At a median follow-up of 12 months (1–46 months), no patients had more than mild regurgitation, and 4 had a mean right ventricular outflow tract gradient ≥30 mm Hg. During follow-up, there were 2 stent fractures, 3 cases of endocarditis (2 managed with surgical explant), and 2 deaths that were unrelated to the Melody valve. Conclusions—: Transcatheter pulmonary valve implantation using the Melody valve within BPVs can be accomplished with a high rate of success, low procedure-related morbidity and mortality, and excellent short-term results. The findings of this preliminary multicenter experience suggest that the Melody valve is an effective transcatheter treatment option for failed BPVs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circinterventions.112.972216

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 164

Metadata

Authors
Gillespie, M. J., Rome, J. J., Levi, D. S., Williams, R. J., Rhodes, J. F., Cheatham, J. P., Hellenbrand, W. E., Jones, T. K., Vincent, J. A., Zahn, E. M., & McElhinney, D. B.
Venue
Circulation: Cardiovascular Interventions
Published
2012-12
Volume
5
Issue
6
Pages
862-870
ISSN
  • 1941-7632 (ISSN-L)
  • 1941-7640
OpenAlex
W1976881664
Cited by
164
References
0
FWCI
10.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Melody Valve Implant Within Failed Bioprosthetic Valves in the Pulmonary Position: A Multicenter Experience. https://app.cochat.ai/papers/10.1161/circinterventions.112.972216
The paper
Gillespie, M. J., Rome, J. J., Levi, D. S., Williams, R. J., Rhodes, J. F., Cheatham, J. P., Hellenbrand, W. E., Jones, T. K., Vincent, J. A., Zahn, E. M., & McElhinney, D. B. (2012). Melody Valve Implant Within Failed Bioprosthetic Valves in the Pulmonary Position: A Multicenter Experience. Circulation: Cardiovascular Interventions. https://doi.org/10.1161/circinterventions.112.972216

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.