CoChat

Outcomes in High-Risk Pulmonary Embolism Patients Undergoing FlowTriever Mechanical Thrombectomy or Other Contemporary Therapies: Results From the FLAME Study

Open access
Silver, Mitchell J., Gibson, C. Michael, Giri, Jay, Khandhar, Sameer, Jaber, Wissam, Toma, Catalin, Mina, Bushra, Bowers, Terry, Greenspon, Lee, Kado, Herman, Zlotnick, David M., Chakravarthy, Mithun, DuCoffe, Aaron R., Butros, Paul, Horowitz, James M. · 2023 · Circulation: Cardiovascular Interventions
Cited by 188

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Background: Hemodynamically unstable high-risk, or massive, pulmonary embolism (PE) has a reported in-hospital mortality of over 25%. Systemic thrombolysis is the guideline-recommended treatment despite limited evidence. The FLAME study (FlowTriever for Acute Massive PE) was designed to generate evidence for interventional treatments in high-risk PE. Methods: The FLAME study was a prospective, multicenter, nonrandomized, parallel group, observational study of high-risk PE. Eligible patients were treated with FlowTriever mechanical thrombectomy (FlowTriever Arm) or with other contemporary therapies (Context Arm). The primary end point was an in-hospital composite of all-cause mortality, bailout to an alternate thrombus removal strategy, clinical deterioration, and major bleeding. This was compared in the FlowTriever Arm to a prespecified performance goal derived from a contemporary systematic review and meta-analysis. Results: A total of 53 patients were enrolled in the FlowTriever Arm and 61 in the Context Arm. Context Arm patients were primarily treated with systemic thrombolysis (68.9%) or anticoagulation alone (23.0%). The primary end point was reached in 9/53 (17.0%) FlowTriever Arm patients, significantly lower than the 32.0% performance goal ( P <0.01). The primary end point was reached in 39/61 (63.9%) Context Arm patients. In-hospital mortality occurred in 1/53 (1.9%) patients in the FlowTriever Arm and in 18/61 (29.5%) patients in the Context Arm. Conclusions: Among patients selected for mechanical thrombectomy with the FlowTriever System, a significantly lower associated rate of in-hospital adverse clinical outcomes was observed compared with a prespecified performance goal, primarily driven by low all-cause mortality of 1.9%. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04795167.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circinterventions.123.013406

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Silver, M. J., Gibson, C. M., Giri, J., Khandhar, S., Jaber, W., Toma, C., Mina, B., Bowers, T., Greenspon, L., Kado, H., Zlotnick, D. M., Chakravarthy, M., DuCoffe, A. R., Butros, P., & Horowitz, J. M.
Venue
Circulation: Cardiovascular Interventions
Published
2023-10
Volume
16
Issue
10
Pages
e013406-e013406
ISSN
  • 1941-7632 (ISSN-L)
  • 1941-7640
OpenAlex
W4387709887
Cited by
188
References
28
FWCI
41.85
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.