Patient Registries of Acute Coronary Syndrome: Assessing or Biasing the Clinical Real World Data?

Open access
Ferreira-González, Ignacio, Marsal, Josep R., Mitjavila, Francesca, Parada, Antoni, Ribera, Aida, Cascant, Purificación, Soriano, Núria, Sánchez, Pedro L., Arós, Fernando, Heras, Magda, Bueno, Héctor, Marrugat, Jaume, Cuñat, José, Civeira, Emilia, Permanyer-Miralda, Gaietà · 2009 · Circulation: Cardiovascular Quality and Outcomes
Cited by 73

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background— The risk of selection bias in registries and its consequences are relatively unexplored. We sought to assess selection bias in a recent registry about acute coronary syndrome and to explore the way of conducting and reporting patient registries of acute coronary syndrome. Methods and Results— We analyzed data from patients of a national acute coronary syndrome registry undergoing an audit about the comprehensiveness of the recruitment/inclusion. Patients initially included by hospital investigators (n=3265) were compared to eligible nonincluded (missed) patients (n=1439). We assessed, for 25 exposure variables, the deviation of the in-hospital mortality relative risks calculated in the initial sample from the actual relative risks. Missed patients were of higher risk and received less recommended therapies than the included patients. In-hospital mortality was almost 3 times higher in the missed population (9.34% [95% CI, 7.84 to 10.85] versus 3.9% [95% CI, 2.89 to 4.92]). Initial relative risks diverged from the actual relative risks more than expected by chance ( P <0.05) in 21 variables, being higher than 10% in 17 variables. This deviation persisted on a smaller degree on multivariable analysis. Additionally, we reviewed a sample of 129 patient registries focused on acute coronary syndrome published in thirteen journals, collecting information on good registry performance items. Only in 38 (29.4%) and 48 (37.2%) registries was any audit of recruitment/inclusion and data abstraction, respectively, mentioned. Only 4 (3.1%) authors acknowledged potential selection bias because of incomplete recruitment. Conclusions— Irregular inclusion can introduce substantial systematic bias in registries. This problem has not been explicitly addressed in a substantial number of them.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circoutcomes.108.844399

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 73

Metadata

Authors
Ferreira-González, I., Marsal, J. R., Mitjavila, F., Parada, A., Ribera, A., Cascant, P., Soriano, N., Sánchez, P. L., Arós, F., Heras, M., Bueno, H., Marrugat, J., Cuñat, J., Civeira, E., & Permanyer-Miralda, G.
Venue
Circulation: Cardiovascular Quality and Outcomes
Published
2009-11
Volume
2
Issue
6
Pages
540-547
ISSN
  • 1941-7705 (ISSN-L)
  • 1941-7713
OpenAlex
W2165431358
Cited by
73
References
6
FWCI
3.28
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patient Registries of Acute Coronary Syndrome: Assessing or Biasing the Clinical Real World Data? https://app.cochat.ai/papers/10.1161/circoutcomes.108.844399
The paper
Ferreira-González, I., Marsal, J. R., Mitjavila, F., Parada, A., Ribera, A., Cascant, P., Soriano, N., Sánchez, P. L., Arós, F., Heras, M., Bueno, H., Marrugat, J., Cuñat, J., Civeira, E., & Permanyer-Miralda, G. (2009). Patient Registries of Acute Coronary Syndrome: Assessing or Biasing the Clinical Real World Data? Circulation: Cardiovascular Quality and Outcomes. https://doi.org/10.1161/circoutcomes.108.844399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.