Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 203

The DOI matches its Crossref record.

Magnetic Resonance–Based Anatomical Analysis of Scar-Related Ventricular Tachycardia: Implications for Catheter Ablation

Open access
Ashikaga, Hiroshi, Sasano, Tetsuo, Dong, Jun, Zviman, M. Muz, Evers, Robert, Hopenfeld, Bruce, Castro, Valeria, Helm, Robert H., Dickfeld, Timm, Nazarian, Saman, Donahue, J. Kevin, Berger, Ronald D., Calkins, Hugh, Abraham, M. Roselle, Marbán, Eduardo, Lardo, Albert C., McVeigh, Elliot R., Halperin, Henry R.·2007·Circulation Research

Abstract

In catheter ablation of scar-related monomorphic ventricular tachycardia (VT), substrate voltage mapping is used to electrically define the scar during sinus rhythm. However, the electrically defined scar may not accurately reflect the anatomical scar. Magnetic resonance–based visualization of the scar may elucidate the 3D anatomical correlation between the fine structural details of the scar and scar-related VT circuits. We registered VT activation sequence with the 3D scar anatomy derived from high-resolution contrast-enhanced MRI in a swine model of chronic myocardial infarction using epicardial sock electrodes (n=6, epicardial group), which have direct contact with the myocardium where the electrical signal is recorded. In a separate group of animals (n=5, endocardial group), we also assessed the incidence of endocardial reentry in this model using endocardial basket catheters. Ten to 12 weeks after myocardial infarction, sustained monomorphic VT was reproducibly induced in all animals (n=11). In the epicardial group, 21 VT morphologies were induced, of which 4 (19.0%) showed epicardial reentry. The reentry isthmus was characterized by a relatively small volume of viable myocardium bound by the scar tissue at the infarct border zone or over the infarct. In the endocardial group (n=5), 6 VT morphologies were induced, of which 4 (66.7%) showed endocardial reentry. In conclusion, MRI revealed a scar with spatially complex structures, particularly at the isthmus, with substrate for multiple VT morphologies after a single ischemic episode. Magnetic resonance–based visualization of scar morphology would potentially contribute to preprocedural planning for catheter ablation of scar-related, unmappable VT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circresaha.107.158980

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 203

Metadata

Authors
Ashikaga, H., Sasano, T., Dong, J., Zviman, M. M., Evers, R., Hopenfeld, B., Castro, V., Helm, R. H., Dickfeld, T., Nazarian, S., Donahue, J. K., Berger, R. D., Calkins, H., Abraham, M. R., Marbán, E., Lardo, A. C., McVeigh, E. R., & Halperin, H. R.
Venue
Circulation Research
Published
2007-10-26
Volume
101
Issue
9
Pages
939-947
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2118703676
Cited by
203
References
0
FWCI
9.07
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic Resonance–Based Anatomical Analysis of Scar-Related Ventricular Tachycardia: Implications for Catheter Ablation. https://app.cochat.ai/papers/10.1161/circresaha.107.158980
The paper
Ashikaga, H., Sasano, T., Dong, J., Zviman, M. M., Evers, R., Hopenfeld, B., Castro, V., Helm, R. H., Dickfeld, T., Nazarian, S., Donahue, J. K., Berger, R. D., Calkins, H., Abraham, M. R., Marbán, E., Lardo, A. C., McVeigh, E. R., & Halperin, H. R. (2007). Magnetic Resonance–Based Anatomical Analysis of Scar-Related Ventricular Tachycardia: Implications for Catheter Ablation. Circulation Research. https://doi.org/10.1161/circresaha.107.158980

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.