Computer Three-Dimensional Reconstruction of the Atrioventricular Node
Open accessThe DOI matches its Crossref record.
Abstract
Because of its complexity, the atrioventricular node (AVN), remains 1 of the least understood regions of the heart. The aim of the study was to construct a detailed anatomic model of the AVN and relate it to AVN function. The electric activity of a rabbit AVN preparation was imaged using voltage-dependent dye. The preparation was then fixed and sectioned. Sixty-five sections at 60- to 340-μm intervals were stained for histology and immunolabeled for neurofilament (marker of nodal tissue) and connexin43 (gap junction protein). This revealed multiple structures within and around the AVN, including transitional tissue, inferior nodal extension, penetrating bundle, His bundle, atrial and ventricular muscle, central fibrous body, tendon of Todaro, and valves. A 3D anatomically detailed mathematical model (≈13 million element array) of the AVN and surrounding atrium and ventricle, incorporating all cell types, was constructed. Comparison of the model with electric activity recorded in experiments suggests that the inferior nodal extension forms the slow pathway, whereas the transitional tissue forms the fast pathway into the AVN. In addition, it suggests the pacemaker activity of the atrioventricular junction originates in the inferior nodal extension. Computer simulation of the propagation of the action potential through the anatomic model shows how, because of the complex structure of the AVN, reentry (slow–fast and fast–slow) can occur. In summary, a mathematical model of the anatomy of the AVN has been generated that allows AVN conduction to be explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Genesis and Regulation of the Heart Automaticity
Mangoni, M. E., & Nargeot, J. (2008) · Physiological Reviews · doi:10.1152/physrev.00018.2007 · Cited by 600
Models of cardiac tissue electrophysiology: Progress, challenges and open questions
Clayton, R. H., Bernus, O., Cherry, E. M., Dierckx, H., Fenton, F. H., Mirabella, L., Panfilov, A. V., Sachse, F. B., Seemann, G., & Zhang, H. (2011) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2010.05.008 · Cited by 585
Self-citationDevelopment of the Pacemaker Tissues of the Heart
Christoffels, V. M., Smits, G. J., Kispert, A., & Moorman, A. F. M. (2010) · Circulation Research · doi:10.1161/circresaha.109.205419 · Cited by 295
The openCARP simulation environment for cardiac electrophysiology
Plank, G., Loewe, A., Neic, A., Augustin, C., Huang, Y.-L., Gsell, M. A. F., Karabelas, E., Nothstein, M., Prassl, A. J., Sánchez, J., et al. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106223 · Cited by 264
Structure-function relationship in the sinus and atrioventricular nodes
Nikolaidou, T., Aslanidi, O. V., Zhang, H., & Efimov, I. R. (2012) · Pediatric Cardiology · doi:10.1007/s00246-012-0249-0 · Cited by 47
Self-citation
Metadata
- Authors
- Li, J., Greener, I. D., Inada, S., Nikolski, V. P., Yamamoto, M., Hancox, J. C., Zhang, H., Billeter, R., Efimov, I. R., Dobrzynski, H., & Boyett, M. R.
- Venue
- Circulation Research
- Published
- 2008-04-25
- Volume
- 102
- Issue
- 8
- Pages
- 975-985
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2145619195
- Cited by
- 115
- References
- 0
- FWCI
- 7.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer Three-Dimensional Reconstruction of the Atrioventricular Node. https://app.cochat.ai/papers/10.1161/circresaha.108.172403
- The paper
- Li, J., Greener, I. D., Inada, S., Nikolski, V. P., Yamamoto, M., Hancox, J. C., Zhang, H., Billeter, R., Efimov, I. R., Dobrzynski, H., & Boyett, M. R. (2008). Computer Three-Dimensional Reconstruction of the Atrioventricular Node. Circulation Research. https://doi.org/10.1161/circresaha.108.172403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.