Bioresorbable Scaffold: The Emerging Reality and Future Directions
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In the era of drug-eluting stents, large-scale randomized trials and all-comer registries have shown excellent clinical results. However, even the latest-generation drug-eluting stent has not managed to address all the limitations of permanent metallic coronary stents, such as the risks of target lesion revascularization, neoatherosclerosis, preclusion of late lumen enlargement, and the lack of reactive vasomotion. Furthermore, the risk of very late stent, although substantially reduced with newer-generation drug-eluting stent, still remains. These problems were anticipated to be solved with the advent of fully biodegradable devices. Fully bioresorbable coronary scaffolds have been designed to function transiently to prevent acute recoil, but have retained the capability to inhibit neointimal proliferation by eluting immunosuppressive drugs. Nevertheless, long-term follow-up data of the leading bioresorbable scaffold (Absorb) are becoming available and have raised a concern about the relatively higher incidence of scaffold thrombosis. To reduce the rate of clinical events, improvements in the device, as well as implantation procedure, are being evaluated. This review will focus on the current CE-mark approved bioresorbable scaffolds, their basic characteristics, and clinical results. In addition, we summarize the current limitations of bioresorbable scaffold and their possible solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levine, G. N., Bates, E. R., Bittl, J. A., Brindis, R. G., Fihn, S. D., Fleisher, L. A., Granger, C. B., Lange, R. A., Mack, M. J., Mauri, L., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000404 · Cited by 1,355
Cited by
Ali, Z. A., Gao, R., Kimura, T., Onuma, Y., Kereiakes, D. J., Ellis, S. G., Chevalier, B., Vu, M.-T., Zhang, Z., Simonton, C. A., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.031843 · Cited by 189
Self-citationZhou, C., Li, H.-F., Yin, Y.-X., Shi, Z.-Z., Li, T., Feng, X.-Y., Zhang, J.-W., Song, C.-X., Cui, X.-S., Xu, K.-L., et al. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.012 · Cited by 171
“The pulsatility restoration can recover important vessel functions such as the unimpeded vasomotion, which is critical to control blood flow and pressure [46].”
BackgroundBiodegradable stents for coronary artery disease treatment: Recent advances and future perspectives
Hu, T., Yang, C., Lin, S., Yu, Q., & Wang, G. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2018.04.100 · Cited by 163
Ben Amara, H., Martinez, D. C., Shah, F. A., Loo, A. J., Emanuelsson, L., Norlindh, B., Willumeit-Römer, R., Plocinski, T., Swieszkowski, W., Palmquist, A., et al. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.02.014 · Cited by 42
“clinical practice within two primary applications: vascular [5] and orthopedic [6].”
Background
Metadata
- Authors
- Sotomi, Y., Onuma, Y., Collet, C., Tenekecioglu, E., Virmani, R., Kleiman, N. S., & Serruys, P. W.
- Venue
- Circulation Research
- Published
- 2017-04-14
- Volume
- 120
- Issue
- 8
- Pages
- 1341-1352
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2606590083
- Cited by
- 162
- References
- 1
- FWCI
- 19.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioresorbable Scaffold: The Emerging Reality and Future Directions. https://app.cochat.ai/papers/10.1161/circresaha.117.310275
- The paper
- Sotomi, Y., Onuma, Y., Collet, C., Tenekecioglu, E., Virmani, R., Kleiman, N. S., & Serruys, P. W. (2017). Bioresorbable Scaffold: The Emerging Reality and Future Directions. Circulation Research. https://doi.org/10.1161/circresaha.117.310275
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.