CoChat

Intracellular Calcium Dynamics and Anisotropic Reentry in Isolated Canine Pulmonary Veins and Left Atrium

Open access
Chou, Chung-Chuan, Nihei, Motoki, Zhou, Shengmei, Tan, Alex, Kawase, Ayaka, Macias, Edgar S., Fishbein, Michael C., Lin, Shien-Fong, Chen, Peng-Sheng · 2005 · Circulation
Cited by 138

The DOI matches its Crossref record.

Abstract

Background— Rapid activations due to either focal discharge or reentry are often present during atrial fibrillation (AF) in the pulmonary veins (PVs). The mechanisms of these rapid activations are unclear. Methods and Results— We studied 7 isolated, Langendorff-perfused canine left atrial (LA) and PV preparations and used 2 cameras to map membrane potential alone (Vm, n=3) or Vm and intracellular calcium simultaneously (Ca i , n=4). Rapid atrial pacing induced 26 episodes of focal discharge from the proximal PVs in 5 dogs. The cycle lengths were 223±52 ms during ryanodine infusion (n=13) and 133±59 ms during ryanodine plus isoproterenol infusion (n=13). The rise of Ca i preceded Vm activation at the sites of focal discharge in 6 episodes of 2 preparations, compatible with voltage-independent spontaneous Ca i release. Phase singularities during pacing-induced reentry clustered specifically at the PV-LA junction. Periodic acid-Schiff (PAS) stain identified large cells with pale cytoplasm along the endocardium of PV muscle sleeves. There were abrupt changes in myocardial fiber orientation and increased interstitial fibrosis in the PV and at the PV-LA junction. Conclusions— PV muscle sleeves may develop voltage-independent Ca i release, resulting in focal discharge. Focal discharge may also be facilitated by the presence of PAS-positive cells that are compatible with node-like cells. During reentry, phase singularities clustered preferentially at sites of increased anisotropy such as the PV-LA junction. These findings suggest that focal discharge caused by spontaneous calcium release and anisotropic reentry both contribute to rapid activations in the PVs during AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.498758

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 138

Metadata

Authors
Chou, C.-C., Nihei, M., Zhou, S., Tan, A., Kawase, A., Macias, E. S., Fishbein, M. C., Lin, S.-F., & Chen, P.-S.
Venue
Circulation
Published
2005-06-07
Volume
111
Issue
22
Pages
2889-2897
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1974031810
Cited by
138
References
0
FWCI
7.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intracellular Calcium Dynamics and Anisotropic Reentry in Isolated Canine Pulmonary Veins and Left Atrium. https://app.cochat.ai/papers/10.1161/circulationaha.104.498758
The paper
Chou, C.-C., Nihei, M., Zhou, S., Tan, A., Kawase, A., Macias, E. S., Fishbein, M. C., Lin, S.-F., & Chen, P.-S. (2005). Intracellular Calcium Dynamics and Anisotropic Reentry in Isolated Canine Pulmonary Veins and Left Atrium. Circulation. https://doi.org/10.1161/circulationaha.104.498758

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.