Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record.

Volumetric Quantification of Global and Regional Left Ventricular Function From Real-Time Three-Dimensional Echocardiographic Images

Open access
Corsi, Cristiana, Lang, Roberto M., Veronesi, Federico, Weinert, Lynn, Caiani, Enrico G., MacEneaney, Peter, Lamberti, Claudio, Mor-Avi, Victor·2005·Circulation

Abstract

Background—Real-time 3D echocardiographic (RT3DE) data sets contain dynamic volumetric information on cardiac function. However, quantification of left ventricular (LV) function from 3D echocardiographic data is performed on cut-planes extracted from the 3D data sets and thus does not fully exploit the volumetric information. Accordingly, we developed a volumetric analysis technique aimed at quantification of global and regional LV function. Methods and Results—RT3DE images obtained in 30 patients (Philips 7500) were analyzed by use of custom software based on the level-set approach for semiautomated detection of LV endocardial surface throughout the cardiac cycle, from which global and regional LV volume (LVV)–time and wall motion (WM)–time curves were obtained. The study design included 3 protocols. In protocol 1, time curves obtained in 16 patients were compared point-by-point with MRI data (linear regression and Bland-Altman analyses). Global LVV correlated highly with MRI (r=0.98;y=0.99 x+2.3) with minimal bias (1.4 mL) and narrow limits of agreement (±20 mL). WM correlated highly only in basal and midventricular segments (r=0.88;y=0.85 x+0.7). In protocol 2, we tested the ability of this technique to differentiate populations with known differences in LV function by studying 9 patients with dilated cardiomyopathy and 9 normal subjects. All calculated indices of global and regional systolic and diastolic LV function were significantly different between the groups. In protocol 3, we tested the feasibility of automated detection of regional WM abnormalities in 11 patients. In each segment, abnormality was detected when regional shortening fraction was below a threshold obtained in normal subjects. The automated detection agreed with expert interpretation of 2D WM in 86% of segments. Conclusions—Volumetric analysis of RT3DE data is clinically feasible and allows fast, semiautomated, dynamic measurement of LVV and automated detection of regional WM abnormalities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.513689

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 244

Metadata

Authors
Corsi, C., Lang, R. M., Veronesi, F., Weinert, L., Caiani, E. G., MacEneaney, P., Lamberti, C., & Mor-Avi, V.
Venue
Circulation
Published
2005-08-23
Volume
112
Issue
8
Pages
1161-1170
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2092081754
Cited by
244
References
0
FWCI
19.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Volumetric Quantification of Global and Regional Left Ventricular Function From Real-Time Three-Dimensional Echocardiographic Images. https://app.cochat.ai/papers/10.1161/circulationaha.104.513689
The paper
Corsi, C., Lang, R. M., Veronesi, F., Weinert, L., Caiani, E. G., MacEneaney, P., Lamberti, C., & Mor-Avi, V. (2005). Volumetric Quantification of Global and Regional Left Ventricular Function From Real-Time Three-Dimensional Echocardiographic Images. Circulation. https://doi.org/10.1161/circulationaha.104.513689

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.