Cited by 253Cardiovascular Function and Risk FactorsCardiac Imaging and DiagnosticsCardiac Valve Diseases and Treatments

Left ventricular volume measurement with echocardiography: a comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging

Open access
Jenkins, C., Moir, S., Chan, J., Rakhit, D., Haluska, B., Marwick, T. H.·2008·European Heart Journal

Abstract

AIMS: Both contrast enhanced (CE) two-dimensional echocardiography (2DE) and three-dimensional echocardiography (3DE) have been proposed as techniques to improve the accuracy of left ventricular (LV) volume measurements. We sought to examine the accuracy of non-contrast (NC) and CE-2DE and 3DE for calculation of LV volumes and ejection fraction (EF), relative to cardiac magnetic resonance imaging (MRI). METHODS AND RESULTS: We studied 50 patients (46 men, age 63 +/- 10 year) with past myocardial infarction who underwent echocardiographic assessment of LV volume and function. All patients sequentially underwent NC-2DE followed by NC-3DE. CE-2DE and CE-3DE were acquired during contrast infusion. Resting echocardiographic image quality was evaluated on the basis of NC-2DE. The mean LV end-diastolic volume (LVEDV) of the group by MRI was 207 +/- 79 mL and was underestimated by 2DE (125 +/- 54 mL, P = 0.005), and less by CE-2DE (172 +/- 58 mL, P = 0.02) or 3DE (177 +/- 64 mL, P = 0.08), but EDV was comparable by CE-3DE (196 +/- 69 mL, P = 0.16). Limits of agreement with MRI were similar for NC-3DE and CE-2DE, with the best results for CE-3D. Results were similar for calculation of LVESV. Patients were categorized into groups of EF (< or =35, 35-50, >50%) by MRI. NC-2DE demonstrated a 68% agreement (kappa 0.45, P = 0.001), CE-2DE a 62% agreement (kappa 0.20, P = 136), NC-3DE a 74% agreement (kappa 0.39, P = 0.005) and CE-3DE an 80% agreement (kappa 0.56, P < 0.001). CONCLUSION: CE-2DE is analogous to NC-3DE in accurate categorization of LV function. However, CE-3DE is feasible and superior to other NC- and CE-techniques in patients with previous infarction.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehn484

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Echocardiography LVEF measurement is less precise relative to other approaches such as magnetic resonance imaging.

    “This might also be attributable to a lack of precision in LVEF measurement by echocardiography, which has shown to be less precise relative to other approaches, such as magnetic resonance imaging27,28.”

    From Detection of left ventricular systolic dysfunction from single-lead electrocardiography adapted for portable and wearable devices (2023) · cites this paper as [28]

    The Introduction and ‘Limitations of each technique’ sections (page not specified) describe poor reproducibility and observer variability for non-contrast 2D echocardiography, supporting the concern about its precision. But the Introduction also says contrast enhancement can bring inter-observer reproducibility to a level comparable with MRI, so the claim is too broad for echocardiography generally. (LLM, conf=0.85)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 22

  1. Gregoratos G, Abrams J, Epstein AE, Freedman RA, Hayes DL, Hlatky MA, Kerber RE, Naccarelli GV, Schoenfeld MH, Silka MJ, Winters SL, ACC/AHA/ NASPE 2002 guideline update for implantation of cardiac pacemakers antiarrhyth- mia devices: summary article. A report of the American College of Cardiology/ American Heart Association Task Force on Practice Guidelines (ACC/AHA/ NASPE Committee to Update the 1998 Pacemaker Guidelines). J Cardiovasc Elec- trophysiol 2002;13:1183 -1199.
  2. Bonow RO, Carabello B, de Leon AC Jr, Edmunds H Jr, Fedderly BJ, Freed MD, Gaasch WH, McKay CR, Nishimura RA, O'Gara PT, O'Rourke RA, Rahimtoola SH. Guidelines for the management of patients with valvular heart disease: executive summary. A report of the American College of Cardiology/ American Heart Association Task Force on Practice Guidelines (Committee on Management of Patients with Valvular Heart Disease). Circulation 1998;98: 1949 -1984.
  3. Kuecherer HF, Kee LL, Modin G, Cheitlin MD, Schiller NB. Echocardiography in serial evaluation of left ventricular systolic and diastolic function: importance of image acquisition, quantitation, and physiologic variability in clinical and investiga- tional applications. J Am Soc Echocardiogr 1991;4:203 -214.
  4. Bellenger NG, Burgess MI, Ray SG, Lahiri A, Coats AJS, Cleland JGF, Pennell DJ. Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J 2000;21:1387 -1396.
  5. Erbel R, Schweizer P, Lambertz H, Henn G, Meyer J, Krebs W, Effert S. Echoventriculography-a simultaneous analysis of two-dimensional echocardio- graphy and cineventriculography. Circulation 1983;67:205 -215.
  6. Bernard Y, Meneveau N, Boucher S, Magnin D, Anguenot T, Schiele F, Vuillemenot A, Bassand J-P. Lack of agreement between left ventricular volumes and ejection fraction determined by two-dimensional echocardiography and contrast cineangiography in postinfarction patients. Echocardiography 2001;18: 113 -122.
  7. Hundley WG, Kizilbash AM, Afridi I, Franco F, Peshock R, Grayburn PA. Admin- istration of an intravenous perfluorocarbon contrast agent improves echocardiographic determination of left ventricular volumes and ejection fraction: comparison with cine magnetic resonance imaging. J Am Coll Cardiol 1998;32: 1426 -1432.
  8. Malm S, Frigstad S, Sagberg E, Larsson H, Skjaerpe T. Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echo- cardiography: a comparison with magnetic resonance imaging. J Am Coll Cardiol 2004;44:1030 -1035.
  9. Thomson HL, Basmadjian AJ, Rainbird AJ, Razavi M, Avierinos J-F, Pellikka PA, Bailey KR, Breen JF, Enriquez-Sarano M. Contrast echocardiography improves the accuracy and reproducibility of left ventricular remodeling measurements: a prospective, randomly assigned, blinded study. J Am Coll Cardiol 2001;38: 867 -875.
  10. Hoffmann R, von Bardeleben S, ten Cate F, Borges AC, Kasprzak J, Firschke C, Lafitte S, Al-Saadi N, Kuntz-Hehner S, Greis C, Becher H, Vanoverschelde JL. The use of contrast echocardiography: a matter of clinical judgement. Eur Heart J 2005;26:1565 -1566.
  11. Jenkins C, Bricknell K, Hanekom L, Marwick TH. Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. J Am Coll Cardiol 2004;44:878 -886.
  12. Corsi C, Lang RM, Veronesi F, Weinert L, Caiani EG, MacEneaney P, Lamberti C, Mor-Avi V. Volumetric quantification of global and regional left ventricular func- tion from real-time three-dimensional echocardiographic images. Circulation 2005; 112:1161 -1170.
  13. Grayburn PA, Mulvagh S, Crouse L. Left ventricular opacification at rest and during stress. Am J Cardiol 2002;90:21J -27J.
  14. Rainbird AJ, Mulvagh SL, Oh JK, McCully RB, Klarich KW, Shub C, Mahoney DW, Pellikka PA. Contrast dobutamine stress echocardiography: clinical practice assessment in 300 consecutive patients. J Am Soc Echocardiogr 2001;14:378 -385.
  15. Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H, Gutgesell H, Reichek N, Sahn D, Schnittger I. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 1989;2:358 -367.
  16. Hibberd MG, Chuang ML, Beaudin RA, Riley MF, Mooney G, Fearnside JT, Manning WJ, Douglas PS. Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction. Am Heart J 2000;140:469 -475.
  17. Mulvagh SL, DeMaria AN, Feinstein SB, Burns PN, Kaul S, Miller JG, Monaghan M, Porter TR, Shaw LJ, Villanueva FS. Contrast echocardiography: current and future applications. J Am Soc Echocardiogr 2000;13:331 -342.
  18. Hoffmann R, von Bardeleben S, Kasprzak JD, Borges AC, ten Cate F, Firschke C, Lafitte S, Al-Saadi N, Kuntz-Hehner S, Horstick G, Greis C, Engelhardt M, Vanoverschelde JL, Becher H. Analysis of regional left ventricular function by cine- ventriculography, cardiac magnetic resonance imaging, and unenhanced and contrast-enhanced echocardiography: a multicenter comparison of methods. J Am Coll Cardiol 2006;47:121 -128.
  19. Hoffmann R, Borges AC, Kasprzak JD, von Bardeleben S, Firschke C, Greis C, Engelhardt M, Becher H, Vanoverschelde JL. Analysis of myocardial perfusion or myocardial function for detection of regional myocardial abnormalities. An echocardiographic multicenter comparison study using myocardial contrast echo- cardiography and 2D echocardiography. Eur J Echocardiogr 2007;8:438 -448.
  20. Yao GH, Li F, Zhang C, Zhang PF, Zhang M, Zhao YX, Li XN, Ding SF, Zhong L, Zhang Y. How many planes are required to get an accurate and timesaving measurement of left ventricular volume and function by real-time three- dimensional echocardiography in acute myocardial infarction? Ultrasound Med Biol 2007;33:1572 -1578.
  21. King DL, Harrison MR, King DL Jr, Gopal AS, Kwan OL, DeMaria AN. Ultrasound beam orientation during standard two-dimensional imaging: assessment by three- dimensional echocardiography. J Am Soc Echocardiogr 1992;5:569 -576.
  22. Lim TK, Burden L, Janardhanan R, Ping C, Moon J, Pennell D, Senior R. Improved accuracy of low-power contrast echocardiography for the assessment of left ven- tricular remodeling compared with unenhanced harmonic echocardiography after acute myocardial infarction: comparison with cardiovascular magnetic resonance imaging. J Am Soc Echocardiogr 2005;18:1203 -1207.

Cited by

Sorted by citations

Authors
Jenkins, C., Moir, S., Chan, J., Rakhit, D., Haluska, B., & Marwick, T. H.
Affiliations
The University of Queensland (AU)
Corresponding author
Marwick, T. H.
Venue
European Heart Journal
Published
2008-07-28
Volume
30
Issue
1
Pages
98-106
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2052900937
Cited by
253
References
0
Citations by year
2026: 6 · 2025: 9 · 2024: 8 · 2023: 15 · 2022: 12 · 2021: 8 · 2020: 6 · 2019: 18 · 2018: 10 · 2017: 20 · 2016: 16 · 2015: 15 · 2014: 24 · 2013: 12 · 2012: 26
FWCI
11.69
Type
journal article
Language
en
Open access
Locations
  • European Heart Journal (publishedVersion)
  • PubMed (publishedVersion)
  • eCite Digital Repository (University of Tasmania) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
Keywords
left ventricular volume, left ventricular ejection fraction, contrast echocardiography, three-dimensional echocardiography, left ventricular opacification, cardiac magnetic resonance imaging, end-diastolic volume, end-systolic volume, myocardial infarction, measurement accuracy, left ventricular function assessment, limits of agreement, myocardial perfusion imaging
MeSH terms
Aged, Analysis of Variance, Contrast Media, Echocardiography, Female, Heart Ventricles, Humans, Image Enhancement, Magnetic Resonance Imaging, Male, Middle Aged, Myocardial Infarction, Prospective Studies, Sensitivity and Specificity, Stroke Volume, Observer Variation, Ventricular Dysfunction, Left, Echocardiography, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review