Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 307

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Symbolic Dynamics of Heart Rate Variability: A Probe to Investigate Cardiac Autonomic Modulation

Guzzetti, Stefano, Borroni, Ester, Garbelli, Pietro E., Ceriani, Elisa, Bella, Paolo Della, Montano, Nicola, Cogliati, Chiara, Somers, Virend K., Mallani, Alberto, Porta, Alberto·2005·Circulation

Abstract

Background— Sympathetic and parasympathetic systems are considered the principal rapidly reacting systems that control heart rate. Methods and Results— We propose a symbolic analysis series to quantify the prevalence of sympathetic or parasympathetic cardiac modulation. This analysis decomposes the heart rate variability series in patterns lasting 3 beats and classifies them into 3 categories: nonvariable, variable, and very variable patterns referred to as 0V, 1V, and 2V patterns. First, we applied this method to experimental and pharmacological conditions characterized by sympathetic activation (tilt test, handgrip, nitroprusside, and high-dose atropine administration) or parasympathetic activation (phenylephrine and low-dose atropine administration) in 60 healthy subjects. An increase in sympathetic modulation and a vagal withdrawal elicited a significant increase in 0V patterns and a decrease in 2V patterns, whereas parasympathetic dominance induced the opposite, reflecting a reciprocal sympathovagal balance. The second part of the study considered a series of 300 beats before the onset of major arrhythmic events in patients with an implantable cardioverter-defibrillator. Symbolic analysis detected an increase in the percentage of 0V patterns before the onset of major arrhythmias compared with baseline (41.6±3.9% and 24.4±2.9%, respectively; P <0.01), indicating a sympathetic prevalence. On the other hand, the 2V patterns did not decrease before major arrhythmias, suggesting the presence of nonreciprocal autonomic modulations. Conclusions— Symbolic analysis of 3 beat sequences takes into account the different time course of sympathetic and parasympathetic cardiac modulations and seems appropriate for elucidating the neural pathophysiological mechanisms occurring during the short periods that precede acute cardiac events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.518449

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 307

Metadata

Authors
Guzzetti, S., Borroni, E., Garbelli, P. E., Ceriani, E., Bella, P. D., Montano, N., Cogliati, C., Somers, V. K., Mallani, A., & Porta, A.
Venue
Circulation
Published
2005-07-26
Volume
112
Issue
4
Pages
465-470
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2144446077
Cited by
307
References
33
FWCI
5.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Symbolic Dynamics of Heart Rate Variability: A Probe to Investigate Cardiac Autonomic Modulation. https://app.cochat.ai/papers/10.1161/circulationaha.104.518449
The paper
Guzzetti, S., Borroni, E., Garbelli, P. E., Ceriani, E., Bella, P. D., Montano, N., Cogliati, C., Somers, V. K., Mallani, A., & Porta, A. (2005). Symbolic Dynamics of Heart Rate Variability: A Probe to Investigate Cardiac Autonomic Modulation. Circulation. https://doi.org/10.1161/circulationaha.104.518449

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.