The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Appropriate and Inappropriate Ventricular Therapies, Quality of Life, and Mortality Among Primary and Secondary Prevention Implantable Cardioverter Defibrillator Patients: Results From the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) Trial
Open accessAbstract
Background— Implantable cardioverter defibrillators (ICDs) reduce mortality in primary and secondary prevention. Quality of life, mortality, appropriate therapies for specific ventricular rhythms, and inappropriate therapies for supraventricular tachycardia (SVT) were compared among 582 patients (primary prevention=248; secondary prevention=334) in PainFREE Rx II, a 634-patient prospective, randomized study of antitachycardia pacing or shocks for fast ventricular tachycardia (FVT). Methods and Results— ICDs were programmed identically with 3 zones (ventricular tachycardia [VT] <188 bpm; FVT=188 to 250 bpm; ventricular fibrillation [VF] >250 bpm) but randomized to antitachycardia pacing or shock as initial therapy for FVT. All treated episodes with electrograms were adjudicated. Primary prevention patients had lower ejection fractions and more coronary artery disease. β-Blocker use, antiarrhythmic drug use, and follow-up duration were similar. Over 11±3 months, 1563 treated episodes were classified as VT (n=740), FVT (n=350), VF (n=77), and SVT (n=396). The distribution of VT, FVT, and VF was not different between primary and secondary prevention patients (respectively, VT 52% versus 54%, FVT 35% versus 35%, and VF 14% versus 10%). More secondary prevention patients had appropriate therapies (26% versus 18%, P =0.02), but among these patients, the median number of episodes per patient was similar. Inappropriate therapies occurred in 15% of both groups and accounted for similar proportions of all detected and treated episodes (46% in primary prevention patients versus 34% in secondary prevention patients, P =0.09). Quality of life improved modestly in both groups, and mortality was similar. Conclusions— Primary prevention patients are slightly less likely to have appropriate therapies than secondary prevention patients, but episode density is similar among patients with appropriate therapies. SVT resulted in more than one third of therapies in both groups, but quality of life and mortality were similar.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · PubMed · Cited by 33,716
The MOS 36-ltem Short-Form Health Survey (SF-36): I. Conceptual Framework and Item Selection
Ware, J. E., & Sherbourne, C. D. (1992) · Medical Care · doi:10.1097/00005650-199206000-00002 · Cited by 30,033
Longitudinal data analysis using generalized linear models
LIANG, K.-Y., & ZEGER, S. L. (1986) · Biometrika · doi:10.1093/biomet/73.1.13 · Cited by 18,550
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
A sharper Bonferroni procedure for multiple tests of significance
HOCHBERG, Y. (1988) · Biometrika · doi:10.1093/biomet/75.4.800 · Cited by 4,829
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
(1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,232
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
Prophylactic Defibrillator Implantation in Patients with Nonischemic Dilated Cardiomyopathy
Kadish, A., Dyer, A., Daubert, J. P., Quigg, R., Estes, N. A. M., Anderson, K. P., Calkins, H., Hoch, D., Goldberger, J., Shalaby, A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa033088 · Cited by 2,080
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Self-citationEpstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Self-citationInappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
Daubert, J. P., Zareba, W., Cannom, D. S., McNitt, S., Rosero, S. Z., Wang, P., Schuger, C., Steinberg, J. S., Higgins, S. L., Wilber, D. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.073 · Cited by 813
Tracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 732
Khairy, P., Van Hare, G. F., Balaji, S., Berul, C. I., Cecchin, F., Cohen, M. I., Daniels, C. J., Deal, B. J., Dearani, J. A., Groot, N. D., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.05.009 · Cited by 709
Metadata
- Authors
- Sweeney, M. O., Wathen, M. S., Volosin, K., Abdalla, I., DeGroot, P. J., Otterness, M. F., & Stark, A. J.
- Venue
- Circulation
- Published
- 2005-06-07
- Volume
- 111
- Issue
- 22
- Pages
- 2898-2905
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2053506917
- Cited by
- 276
- References
- 27
- FWCI
- 13.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Appropriate and Inappropriate Ventricular Therapies, Quality of Life, and Mortality Among Primary and Secondary Prevention Implantable Cardioverter Defibrillator Patients: Results From the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) Trial. https://app.cochat.ai/papers/10.1161/circulationaha.104.526673
- The paper
- Sweeney, M. O., Wathen, M. S., Volosin, K., Abdalla, I., DeGroot, P. J., Otterness, M. F., & Stark, A. J. (2005). Appropriate and Inappropriate Ventricular Therapies, Quality of Life, and Mortality Among Primary and Secondary Prevention Implantable Cardioverter Defibrillator Patients: Results From the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) Trial. Circulation. https://doi.org/10.1161/circulationaha.104.526673
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.