Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 705

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

New Noninvasive Method for Assessment of Left Ventricular Rotation: Speckle Tracking Echocardiography

Open access
Helle-Valle, Thomas, Crosby, Jonas, Edvardsen, Thor, Lyseggen, Erik, Amundsen, Brage H., Smith, Hans-Jørgen, Rosen, Boaz D., Lima, João A.C., Torp, Hans, Ihlen, Halfdan, Smiseth, Otto A.·2005·Circulation

Abstract

Background— Left ventricular (LV) torsion is due to oppositely directed apical and basal rotation and has been proposed as a sensitive marker of LV function. In the present study, we introduce and validate speckle tracking echocardiography (STE) as a method for assessment of LV rotation and torsion. Methods and Results— Apical and basal rotation by STE was measured from short-axis images by automatic frame-to-frame tracking of gray-scale speckle patterns. Rotation was calculated as the average angular displacement of 9 regions relative to the center of a best-fit circle through the same regions. As reference methods we used sonomicrometry in anesthetized dogs during baseline, dobutamine infusion, and apical ischemia, and magnetic resonance imaging (MRI) tagging in healthy humans. In dogs, the mean peak apical rotation was −3.7±1.2° (±SD) and −4.1±1.2°, and basal rotation was 1.9±1.5° and 2.0±1.2° by sonomicrometry and STE, respectively. Rotations by both methods increased ( P <0.001) during dobutamine infusion. Apical rotation by both methods decreased during left anterior descending coronary artery occlusion ( P <0.007), whereas basal rotation was unchanged. In healthy humans, apical rotation was −11.6±3.8° and −10.9±3.3°, and basal rotation was 4.8±1.7° and 4.6±1.3° by MRI tagging and STE, respectively. Torsion measurement by STE showed good correlation and agreement with sonomicrometry ( r =0.94, P <0.001) and MRI ( r =0.85, P <0.001). Conclusions— The present study demonstrates that regional LV rotation and torsion can be measured accurately by STE, suggesting a new echocardiographic approach for quantification of LV systolic function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.531558

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 705

Metadata

Authors
Helle-Valle, T., Crosby, J., Edvardsen, T., Lyseggen, E., Amundsen, B. H., Smith, H.-J., Rosen, B. D., Lima, J. A. C., Torp, H., Ihlen, H., & Smiseth, O. A.
Venue
Circulation
Published
2005-11-15
Volume
112
Issue
20
Pages
3149-3156
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2131916402
Cited by
705
References
2
FWCI
29.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New Noninvasive Method for Assessment of Left Ventricular Rotation: Speckle Tracking Echocardiography. https://app.cochat.ai/papers/10.1161/circulationaha.104.531558
The paper
Helle-Valle, T., Crosby, J., Edvardsen, T., Lyseggen, E., Amundsen, B. H., Smith, H.-J., Rosen, B. D., Lima, J. A. C., Torp, H., Ihlen, H., & Smiseth, O. A. (2005). New Noninvasive Method for Assessment of Left Ventricular Rotation: Speckle Tracking Echocardiography. Circulation. https://doi.org/10.1161/circulationaha.104.531558

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.