Metabolic Syndrome Is Associated With Faster Degeneration of Bioprosthetic Valves

Open access
Briand, Martin, Pibarot, Philippe, Després, Jean-Pierre, Voisine, Pierre, Dumesnil, Jean G., Dagenais, François, Mathieu, Patrick · 2006 · Circulation
Cited by 129

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background— Several studies have reported similarities between calcification of the native aortic valve and atherosclerosis. Recent studies also suggested that hypercholesterolemia may be a risk factor for calcific degeneration of bioprosthetic valves. The metabolic syndrome (MS) is associated with a higher risk of vascular atherosclerosis. We thus hypothesized that the atherogenic features of MS could accelerate bioprosthetic valve degeneration. Methods and Results— We included 217 patients who underwent aortic valve replacement with a bioprosthetic valve in the study. Of these patients, 71 patients (33%) had MS defined according to the modified criteria proposed by the National Cholesterol Education Program Adult Treatment Panel III. The annualized increase in mean transprosthetic gradient and the worsening of transprosthetic regurgitation measured by Doppler echocardiography were used to assess the deterioration of valve hemodynamic function. Patients with MS had higher progression of gradient (+4±5 mm Hg/year versus +2±2 mm Hg/year, P <0.001), higher proportion of ≥1/3 degree worsening of regurgitation (25% versus 12%, P =0.02), and higher proportion of valve function deterioration defined as regurgitation worsening and/or ≥3 mm Hg/year increase in gradient (41% versus 25%, P =0.02) when compared with patients without MS. On multivariate analysis, MS was an independent predictor of gradient progression ( P =0.01), regurgitation worsening ( P =0.02), and valve function deterioration ( P =0.02). The other independent predictors were diabetes, renal insufficiency, and higher mean gradient at baseline. Conclusions— This is the first study to report that the MS is independently associated with faster bioprosthetic valve degeneration. This study could pave the way for the development of a new medical therapy able to significantly reduce the structural valve deterioration of bioprostheses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.000422

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 129

Metadata

Authors
Briand, M., Pibarot, P., Després, J.-P., Voisine, P., Dumesnil, J. G., Dagenais, F., & Mathieu, P.
Venue
Circulation
Published
2006-07-04
Volume
114
Issue
1_supplement
Pages
I512-7
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2000209404
Cited by
129
References
5
FWCI
5.25
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.