Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Hemodynamic Effects of Long-Term Cardiac Resynchronization Therapy: Analysis by Pressure-Volume Loops

Open access
Steendijk, Paul, Tulner, Sven A., Bax, Jeroen J., Oemrawsingh, Pranobe V., Bleeker, Gabe B., van Erven, Lieselot, Putter, Hein, Verwey, Harriette F., van der Wall, Ernst E., Schalij, Martin J. · 2006 · Circulation

Abstract

Background— Acute hemodynamic effects of cardiac resynchronization therapy (CRT) were reported previously, but detailed invasive studies showing hemodynamic consequences of long-term CRT are not available. Methods and Results— We studied 22 patients scheduled for implantation of a CRT device based on conventional criteria (New York Heart Association class III or IV, left ventricular [LV] ejection fraction <35%, left bundle-branch block, and QRS duration >120 ms). During diagnostic catheterization before CRT, we acquired pressure-volume loops using conductance catheters during atrial pacing at 80, 100, 120, and 140 bpm. Studies were repeated during biventricular pacing at the same heart rates after 6 months of CRT. Our data show a significant clinical benefit of CRT (New York Heart Association class change from 3.1±0.5 to 2.1±0.8; quality-of-life score change from 44±12 to 31±16; and 6-minute hall-walk distance increased from 260±149 to 396±129 m; all P <0.001), improved LV ejection fraction (from 29±10% to 40±13%, P <0.01), decreased end-diastolic pressure (from 18±8 to 13±6 mm Hg, P <0.05), and reverse remodeling (end-diastolic volume decreased from 257±67 to 205±54 mL, P <0.01). Previously reported acute improvements in LV function remained present at 6 months: dP/dt max increased 18%, −dP/dt min increased 13%, and stroke work increased 34% (all P <0.01). Effects of increased heart rate were improved toward more physiological responses for LV ejection fraction, cardiac output, and dP/dt max . Moreover, our study showed improved ventricular-arterial coupling (69% increase, P <0.01) and improved mechanical efficiency (44% increase, P <0.01). Conclusions— Hemodynamic improvements with CRT, previously shown in acute invasive studies, are maintained chronically. In addition, ventricular-arterial coupling, mechanical efficiency, and chronotropic responses are improved after 6 months of CRT. These findings may help to explain the improved functional status and exercise tolerance in patients treated with CRT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.540435

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 160

Metadata

Authors
Steendijk, P., Tulner, S. A., Bax, J. J., Oemrawsingh, P. V., Bleeker, G. B., van Erven, L., Putter, H., Verwey, H. F., van der Wall, E. E., & Schalij, M. J.
Venue
Circulation
Published
2006-03-14
Volume
113
Issue
10
Pages
1295-1304
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2090698327
Cited by
160
References
2
FWCI
12.25
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.