Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 214

The DOI matches its Crossref record.

Impact of Prosthesis-Patient Mismatch on Long-Term Survival in Patients With Small St Jude Medical Mechanical Prostheses in the Aortic Position

Mohty-Echahidi, Dania, Malouf, Joseph F., Girard, Steve E., Schaff, Hartzell V., Grill, Diane E., Enriquez-Sarano, Maurice E., Miller, Fletcher A.·2006·Circulation

Abstract

Background— The impact of aortic prosthesis-patient mismatch (P-PtM) on long-term survival is unclear. Methods and Results— Between 1985 and 2000, 388 patients at Mayo Clinic in Rochester, Minn, underwent aortic valve replacement (AVR) with 19- or 21-mm St Jude Medical prostheses and had transthoracic echocardiography within 1 year after AVR. Mean age of patients was 62±13 years; 69% were female. Prosthesis effective orifice area (EOA) was derived from the continuity equation. P-PtM was classified as severe (indexed EOA ≤0.60 cm 2 /m 2 ), moderate (0.60 cm 2 /m 2 <indexed EOA≤0.85 cm 2 /m 2 ), or not hemodynamically significant (indexed EOA >0.85 cm 2 /m 2 ). P-PtM was severe in 66 patients (17%), moderate in 168 (43%), and not hemodynamically significant in 154 (40%). Patients with severe P-PtM had a significantly larger body surface area ( P <0.0001), higher mean gradient ( P <0.0001), lower preoperative ( P <0.0001) and postoperative ( P <0.0001) ejection fractions, and lower stroke volume ( P <0.0001) and more often received a 19-mm prosthesis ( P =0.0008) than patients with moderate or no hemodynamically significant mismatch. For patients with severe mismatch, 5-year survival rates (72±6%) and 8-year survival rates (41±8%) were significantly less than for patients with moderate mismatch (80±3% and 65±5%; P =0.026) or no hemodynamically significant mismatch (85±3% and 74±5%; P =0.002). On multivariate analysis after adjustment for other predictors of outcome, severe mismatch was associated with higher mortality (hazard ratio 2.18; 95% confidence interval 1.24 to 3.85; P =0.007) and higher incidence of congestive heart failure (hazard ratio 3.1; 95% confidence interval 1.3 to 7.4; P =0.009) than no hemodynamically significant mismatch. Conclusions— Severe P-PtM is an independent predictor of higher long-term mortality and congestive heart failure in patients with small St Jude Medical aortic valve prostheses. For patients undergoing AVR who are at risk of severe mismatch, every effort should be made to use a larger prosthesis or to consider a prosthesis with a larger EOA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.546754

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 214

Metadata

Authors
Mohty-Echahidi, D., Malouf, J. F., Girard, S. E., Schaff, H. V., Grill, D. E., Enriquez-Sarano, M. E., & Miller, F. A.
Venue
Circulation
Published
2006-01-24
Volume
113
Issue
3
Pages
420-426
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2160869660
Cited by
214
References
0
FWCI
14.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of Prosthesis-Patient Mismatch on Long-Term Survival in Patients With Small St Jude Medical Mechanical Prostheses in the Aortic Position. https://app.cochat.ai/papers/10.1161/circulationaha.105.546754
The paper
Mohty-Echahidi, D., Malouf, J. F., Girard, S. E., Schaff, H. V., Grill, D. E., Enriquez-Sarano, M. E., & Miller, F. A. (2006). Impact of Prosthesis-Patient Mismatch on Long-Term Survival in Patients With Small St Jude Medical Mechanical Prostheses in the Aortic Position. Circulation. https://doi.org/10.1161/circulationaha.105.546754

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.