Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 606

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Prosthesis-patient mismatch: definition, clinical impact, and prevention

Open access
Pibarot, P, Dumesnil, J G·2006·Heart

Abstract

Prosthesis-patient mismatch (PPM) is present when the effective orifice area of the inserted prosthetic valve is too small in relation to body size. Its main haemodynamic consequence is to generate higher than expected gradients through normally functioning prosthetic valves. This review updates the present knowledge about the impact of PPM on clinical outcomes. PPM is common (20–70% of aortic valve replacements) and has been shown to be associated with worse haemodynamic function, less regression of left ventricular hypertrophy, more cardiac events, and lower survival. Moreover, as opposed to most other risk factors, PPM can largely be prevented by using a prospective strategy at the time of operation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.2005.067363

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 606

Metadata

Authors
Pibarot, P., & Dumesnil, J. G.
Venue
Heart
Publisher
BMJ
Published
2005-10-26
Volume
92
Issue
8
Pages
1022-1029
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2038851398
Cited by
606
References
25
FWCI
8.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prosthesis-patient mismatch: definition, clinical impact, and prevention. https://app.cochat.ai/papers/10.1136/hrt.2005.067363
The paper
Pibarot, P., & Dumesnil, J. G. (2006). Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart. https://doi.org/10.1136/hrt.2005.067363

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.