CoChat

A Noninvasive Method for Assessing Impaired Diastolic Suction in Patients With Dilated Cardiomyopathy

Open access
Yotti, Raquel, Bermejo, Javier, Antoranz, J. Carlos, Desco, M. Mar, Cortina, Cristina, Rojo-Álvarez, José Luis, Allué, Carmen, Martín, Laura, Moreno, Mar, Serrano, José A., Muñoz, Roberto, García-Fernández, Miguel A. · 2005 · Circulation
Cited by 152

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background— Diastolic suction is a major determinant of early left ventricular filling in animal experiments. However, suction remains incompletely characterized in the clinical setting. Methods and Results— First, we validated a method for measuring the spatio-temporal distributions of diastolic intraventricular pressure gradients and differences (DIVPDs) by digital processing color Doppler M-mode recordings. In 4 pigs, the error of peak DIVPD was 0.0±0.2 mm Hg (intraclass correlation coefficient, 0.95) compared with micromanometry. Forty patients with dilated cardiomyopathy (DCM) and 20 healthy volunteers were studied at baseline and during dobutamine infusion. A positive DIVPD (toward the apex) originated during isovolumic relaxation, reaching its peak shortly after mitral valve opening. Peak DIVPD was less than half in patients with DCM than in control subjects (1.2±0.6 versus 2.5±0.8 mm Hg, P <0.001). Dobutamine increased DIVPD in control subjects by 44% ( P <0.001) but only by 23% in patients with DCM ( P =NS). DIVPDs were the consequence of 2 opposite forces: a driving force caused by local acceleration, and a reversed (opposed to filling) convective force that lowered the total DIVPD by more than one third. In turn, local acceleration correlated with E-wave velocity and ejection fraction, whereas convective deceleration correlated with E-wave velocity and ventriculo:annular disproportion. Convective deceleration was highest among patients showing a restrictive filling pattern. Conclusions— Patients with DCM show an abnormally low diastolic suction and a blunted capacity to recruit suction with stress. By raising the ventriculo:annular disproportion, chamber remodeling proportionally increases convective deceleration and adversely affects left ventricular filling. These previously unreported mechanisms of diastolic dysfunction can be studied by using Doppler echocardiography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.561340

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 152

Metadata

Authors
Yotti, R., Bermejo, J., Antoranz, J. C., Desco, M. M., Cortina, C., Rojo-Álvarez, J. L., Allué, C., Martín, L., Moreno, M., Serrano, J. A., Muñoz, R., & García-Fernández, M. A.
Venue
Circulation
Published
2005-11-08
Volume
112
Issue
19
Pages
2921-2929
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2150682881
Cited by
152
References
1
FWCI
5.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Noninvasive Method for Assessing Impaired Diastolic Suction in Patients With Dilated Cardiomyopathy. https://app.cochat.ai/papers/10.1161/circulationaha.105.561340
The paper
Yotti, R., Bermejo, J., Antoranz, J. C., Desco, M. M., Cortina, C., Rojo-Álvarez, J. L., Allué, C., Martín, L., Moreno, M., Serrano, J. A., Muñoz, R., & García-Fernández, M. A. (2005). A Noninvasive Method for Assessing Impaired Diastolic Suction in Patients With Dilated Cardiomyopathy. Circulation. https://doi.org/10.1161/circulationaha.105.561340

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.