Causes and Consequences of Heart Failure After Prophylactic Implantation of a Defibrillator in the Multicenter Automatic Defibrillator Implantation Trial II

Goldenberg, Ilan, Moss, Arthur J., Hall, W. Jackson, McNitt, Scott, Zareba, Wojciech, Andrews, Mark L., Cannom, David S. · 2006 · Circulation

Abstract

Background— Implantable cardioverter-defibrillator (ICD) therapy may be associated with an increased risk for heart failure (HF). The present study evaluated the frequency, causes, and consequences of HF after ICD implantation. Methods and Results— We performed a retrospective analysis of the clinical factors and outcomes associated with postenrollment HF events in 1218 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial II. The adjusted hazard ratios (HRs) of ICD:conventional therapy for first and recurrent HF events were 1.39 ( P =0.02) and 1.58 ( P <0.001), respectively. The risk was increased among patients who received single-chamber or dual-chamber ICDs. Development of HF was associated with an increased mortality risk (HR, 3.80; P <0.001). Among patients who received a single-chamber ICD, there was a similar survival benefit before and after the development of HF (HR, 0.59 and 0.61, respectively; P =0.92 for difference), whereas among patients with dual-chamber devices, there was a significant reduction in survival benefit after HF (HR, 0.26 and 0.83, respectively; P =0.01 for difference). Within the defibrillator arm of the trial, patients who received life-prolonging therapy from the ICD had an increased risk for first and recurrent HF events (HR, 1.90; P =0.01 and 1.74; P <0.001, respectively). Conclusions— Patients with chronic ischemic heart disease who are treated with either single-chamber or dual-chamber ICDs have improved survival but an increased risk of HF. The present data suggest that ICD therapy transforms sudden death risk to a subsequent HF risk. These findings should direct more attention to the prevention of HF in patients who receive an ICD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.577262

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 220

Metadata

Authors
Goldenberg, I., Moss, A. J., Hall, W. J., McNitt, S., Zareba, W., Andrews, M. L., & Cannom, D. S.
Venue
Circulation
Published
2006-06-20
Volume
113
Issue
24
Pages
2810-2817
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1970873940
Cited by
220
References
5
FWCI
13.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.