Cited by 225

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Effects of Cardiac Resynchronization Therapy With or Without a Defibrillator on Survival and Hospitalizations in Patients With New York Heart Association Class IV Heart Failure

Lindenfeld, JoAnn, Feldman, Arthur M., Saxon, Leslie, Boehmer, John, Carson, Peter, Ghali, Jalal K., Anand, Inder, Singh, Steve, Steinberg, Jonathan S., Jaski, Brian, DeMarco, Teresa, Mann, David, Yong, Patrick, Galle, Elizabeth, Ecklund, Fred, Bristow, Michael·2007·Circulation

Abstract

Background— Cardiac resynchronization therapy (CRT) alone or combined with an implantable defibrillator (CRT-D) has been shown to improve exercise capacity and quality of life and to reduce heart failure (HF) hospitalizations and mortality in patients with New York Heart Association (NYHA) class III and IV HF. There is concern that the device procedure may destabilize these very ill class IV patients. We sought to examine the outcomes of NYHA class IV patients enrolled in the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) trial to assess the potential benefits of CRT and CRT-D. Methods and Results— The COMPANION trial randomized 1520 patients with NYHA class III and IV HF to optimal medical therapy, CRT, or CRT-D. In the class IV patients (n=217), the primary end point of time to death or hospitalization for any cause was significantly improved by both CRT (hazard ratio [HR], 0.64; 95% CI, 0.43 to 0.94; P =0.02) and CRT-D (HR, 0.62; 95% CI, 0.42 to 0.90; P =0.01). Time to all-cause death and HF hospitalization was also significantly improved in both CRT (HR, 0.57; 95% CI, 0.37 to 0.87; P =0.01) and CRT-D (HR, 0.49; 95% CI, 0.32 to 0.75; P =0.001) Time to all-cause death trended to an improvement in both CRT (HR, 0.67; 95% CI, 0.41 to 1.10; P =0.11) and CRT-D (HR, 0.63; 95% CI, 0.39 to 1.03; P =0.06). Time to sudden death appeared to be significantly reduced in the CRT-D group (HR, 0.27; 95% CI, 0.08 to 0.90; P =0.03). There was a nonsignificant reduction in time to HF deaths for both CRT (HR, 0.68; 95% CI, 0.34 to 1.37; P =0.28) and CRT-D (HR, 0.79; 95% CI, 0.41 to 1.52; P =0.48). Conclusions— CRT and CRT-D significantly improve time to all-cause mortality and hospitalizations in NYHA class IV patients, with a trend for improved mortality. These devices should be considered in ambulatory NYHA class IV HF patients similar to those enrolled in COMPANION.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.106.629261

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 225

Metadata

Authors
Lindenfeld, J., Feldman, A. M., Saxon, L., Boehmer, J., Carson, P., Ghali, J. K., Anand, I., Singh, S., Steinberg, J. S., Jaski, B., DeMarco, T., Mann, D., Yong, P., Galle, E., Ecklund, F., & Bristow, M.
Venue
Circulation
Published
2007-01-16
Volume
115
Issue
2
Pages
204-212
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1997360510
Cited by
225
References
6
FWCI
9.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of Cardiac Resynchronization Therapy With or Without a Defibrillator on Survival and Hospitalizations in Patients With New York Heart Association Class IV Heart Failure. https://app.cochat.ai/papers/10.1161/circulationaha.106.629261
The paper
Lindenfeld, J., Feldman, A. M., Saxon, L., Boehmer, J., Carson, P., Ghali, J. K., Anand, I., Singh, S., Steinberg, J. S., Jaski, B., DeMarco, T., Mann, D., Yong, P., Galle, E., Ecklund, F., & Bristow, M. (2007). Effects of Cardiac Resynchronization Therapy With or Without a Defibrillator on Survival and Hospitalizations in Patients With New York Heart Association Class IV Heart Failure. Circulation. https://doi.org/10.1161/circulationaha.106.629261

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.