The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Reduced Ventricular Volumes and Improved Systolic Function With Cardiac Resynchronization Therapy: A Randomized Trial Comparing Simultaneous Biventricular Pacing, Sequential Biventricular Pacing, and Left Ventricular Pacing
Abstract
Background— Cardiac resynchronization therapy has emerged as an important therapy for advanced systolic heart failure. Among available cardiac resynchronization therapy pacing modes that restore ventricular synchrony, it is uncertain whether simultaneous biventricular (BiV), sequential BiV, or left ventricular (LV) pacing is superior. The Device Evaluation of CONTAK RENEWAL 2 and EASYTRAK 2: Assessment of Safety and Effectiveness in Heart Failure (DECREASE-HF) trial is the first randomized trial comparing these 3 cardiac resynchronization therapy modalities. Methods and Results— The DECREASE-HF Trial is a multicenter trial in which 306 patients with New York Heart Association class III or IV heart failure, an LV ejection fraction ≤35%, and a QRS duration ≥150 ms were randomized to simultaneous BiV, sequential BiV, or LV pacing. LV volumes and systolic and diastolic function were assessed with echocardiography at baseline, 3 months, and 6 months. All groups had a significant reduction in LV end-systolic and end-diastolic dimensions ( P <0.001). The simultaneous BiV pacing group had the greatest reduction in LV end-systolic dimension ( P =0.007). Stroke volume ( P <0.001) and LV ejection fraction ( P <0.001) improved in all groups with no difference across groups. Conclusions— Compared with LV pacing, simultaneous BiV pacing was associated with a trend toward greater improvement in LV size. There is little difference between simultaneous BiV pacing and sequential BiV pacing as programmed in this trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
Cited by
Solomon, S. D., Foster, E., Bourgoun, M., Shah, A., Viloria, E., Brown, M. W., Hall, W. J., Pfeffer, M. A., & Moss, A. J. (2010) · Circulation · doi:10.1161/circulationaha.110.955039 · Cited by 339
Self-citationStrocchi, M., Wijesuriya, N., Elliott, M. K., Gillette, K., Neic, A., Mehta, V., Vigmond, E. J., Plank, G., Rinaldi, C. A., & Niederer, S. A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.1049214 · Cited by 8
Metadata
- Authors
- Rao, R. K., Kumar, U. N., Schafer, J., Viloria, E., De Lurgio, D., & Foster, E.
- Venue
- Circulation
- Published
- 2007-04-24
- Volume
- 115
- Issue
- 16
- Pages
- 2136-2144
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2017265142
- Cited by
- 229
- References
- 2
- FWCI
- 14.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduced Ventricular Volumes and Improved Systolic Function With Cardiac Resynchronization Therapy: A Randomized Trial Comparing Simultaneous Biventricular Pacing, Sequential Biventricular Pacing, and Left Ventricular Pacing. https://app.cochat.ai/papers/10.1161/circulationaha.106.634444
- The paper
- Rao, R. K., Kumar, U. N., Schafer, J., Viloria, E., De Lurgio, D., & Foster, E. (2007). Reduced Ventricular Volumes and Improved Systolic Function With Cardiac Resynchronization Therapy: A Randomized Trial Comparing Simultaneous Biventricular Pacing, Sequential Biventricular Pacing, and Left Ventricular Pacing. Circulation. https://doi.org/10.1161/circulationaha.106.634444
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.