Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 339

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Effect of Cardiac Resynchronization Therapy on Reverse Remodeling and Relation to Outcome: Multicenter Automatic Defibrillator Implantation Trial: Cardiac Resynchronization Therapy

Solomon, Scott D., Foster, Elyse, Bourgoun, Mikhail, Shah, Amil, Viloria, Esperanza, Brown, Mary W., Hall, W. Jackson, Pfeffer, Marc A., Moss, Arthur J.·2010·Circulation

Abstract

Background— Cardiac resynchronization therapy (CRT) plus implantation of an implantable cardioverter defibrillator (ICD) reduced the risk of death or heart failure event in patients with mildly symptomatic heart failure, left ventricular dysfunction, and wide QRS complex compared with an ICD only. We assessed echocardiographic changes in patients enrolled in the MADIT-CRT trial (Multicenter Automatic Defibrillator Implantation Trial: Cardiac Resynchronization Therapy) to evaluate whether the improvement in outcomes with CRT plus an ICD was associated with favorable alterations in cardiac size and function. Methods and Results— A total of 1820 patients were randomly assigned to CRT plus an ICD or to an ICD only in a 3:2 ratio. Echocardiographic studies were obtained at baseline and 12 months later in 1372 patients. We compared changes in cardiac size and performance between treatment groups and assessed the relationship between these changes over the first year, as well as subsequent outcomes. Compared with the ICD-only group, the CRT-plus-ICD group had greater improvement in left ventricular end-diastolic volume index (−26.2 versus −7.4 mL/m 2 ), left ventricular end-systolic volume index (−28.7 versus −9.1 mL/m 2 ), left ventricular ejection fraction (11% versus 3%), left atrial volume index (−11.9 versus −4.7 mL/m 2 ), and right ventricular fractional area change (8% versus 5%; P <0.001 for all). Improvement in end-diastolic volume at 1 year was predictive of subsequent death or heart failure, with adjustment for baseline covariates and treatment group; each 10% decrease in end-diastolic volume was associated with a 40% reduction in risk ( P <0.001). Conclusions— CRT resulted in significant improvement in cardiac size and performance compared with an ICD-only strategy in patients with mildly symptomatic heart failure. Improvement in these measures accounted for the outcomes benefit. Clinical Trial Registration Information— URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.110.955039

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 339

Metadata

Authors
Solomon, S. D., Foster, E., Bourgoun, M., Shah, A., Viloria, E., Brown, M. W., Hall, W. J., Pfeffer, M. A., & Moss, A. J.
Venue
Circulation
Published
2010-09-07
Volume
122
Issue
10
Pages
985-992
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2126617892
Cited by
339
References
23
FWCI
24.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Cardiac Resynchronization Therapy on Reverse Remodeling and Relation to Outcome: Multicenter Automatic Defibrillator Implantation Trial: Cardiac Resynchronization Therapy. https://app.cochat.ai/papers/10.1161/circulationaha.110.955039
The paper
Solomon, S. D., Foster, E., Bourgoun, M., Shah, A., Viloria, E., Brown, M. W., Hall, W. J., Pfeffer, M. A., & Moss, A. J. (2010). Effect of Cardiac Resynchronization Therapy on Reverse Remodeling and Relation to Outcome: Multicenter Automatic Defibrillator Implantation Trial: Cardiac Resynchronization Therapy. Circulation. https://doi.org/10.1161/circulationaha.110.955039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.