Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 709

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Prognostic Value of Very Low Plasma Concentrations of Troponin T in Patients With Stable Chronic Heart Failure

Open access
Latini, Roberto, Masson, Serge, Anand, Inder S., Missov, Emil, Carlson, Marjorie, Vago, Tarcisio, Angelici, Laura, Barlera, Simona, Parrinello, Giovanni, Maggioni, Aldo P., Tognoni, Gianni, Cohn, Jay N.·2007·Circulation

Abstract

Background— Circulating cardiac troponin T, a marker of cardiomyocyte injury, predicts adverse outcome in patients with heart failure (HF) but is detectable in only a small fraction of those with chronic stable HF. We assessed the prognostic value of circulating cardiac troponin T in patients with stable chronic HF with a traditional (cTnT) and a new precommercial highly sensitive assay (hsTnT). Methods and Results— Plasma troponin T was measured in 4053 patients with chronic HF enrolled in the Valsartan Heart Failure Trial (Val-HeFT). Troponin T was detectable in 10.4% of the population with the cTnT assay (detection limit ≤0.01 ng/mL) compared with 92.0% with the new hsTnT assay (≤0.001 ng/mL). Patients with cTnT elevation or with hsTnT above the median (0.012 ng/mL) had more severe HF and worse outcome. In Cox proportional hazards models adjusting for clinical risk factors, cTnT was associated with death (780 events; hazard ratio=2.08; 95% confidence interval, 1.72 to 2.52; P <0.0001) and first hospitalization for HF (655 events; hazard ratio=1.55; 95% confidence interval, 1.25 to 1.93; P <0.0001). HsTnT was associated with the risk of death in unadjusted analysis for deciles of concentrations and in multivariable models (hazard ratio=1.05; 95% confidence interval, 1.04 to 1.07 for increments of 0.01 ng/mL; P <0.0001). Addition of hsTnT to well-calibrated models adjusted for clinical risk factors, with or without brain natriuretic peptide, significantly improved prognostic discrimination (C-index, P <0.0001 for both outcomes). Conclusions— In this large population of patients with HF, detectable cTnT predicts adverse outcomes in chronic HF. By the highly sensitive assay, troponin T retains a prognostic value at previously undetectable concentrations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.106.655076

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 709

Metadata

Authors
Latini, R., Masson, S., Anand, I. S., Missov, E., Carlson, M., Vago, T., Angelici, L., Barlera, S., Parrinello, G., Maggioni, A. P., Tognoni, G., & Cohn, J. N.
Venue
Circulation
Published
2007-09-11
Volume
116
Issue
11
Pages
1242-1249
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1966329493
Cited by
709
References
5
FWCI
30.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prognostic Value of Very Low Plasma Concentrations of Troponin T in Patients With Stable Chronic Heart Failure. https://app.cochat.ai/papers/10.1161/circulationaha.106.655076
The paper
Latini, R., Masson, S., Anand, I. S., Missov, E., Carlson, M., Vago, T., Angelici, L., Barlera, S., Parrinello, G., Maggioni, A. P., Tognoni, G., & Cohn, J. N. (2007). Prognostic Value of Very Low Plasma Concentrations of Troponin T in Patients With Stable Chronic Heart Failure. Circulation. https://doi.org/10.1161/circulationaha.106.655076

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.