The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Transapical Minimally Invasive Aortic Valve Implantation: Multicenter Experience
Abstract
Background— To evaluate initial multicenter results with minimally invasive transapical aortic valve implantation (TAP-AVI) for high risk patients with aortic stenosis. Methods and Results— TAP-AVI was performed via a small anterolateral minithoracotomy with or without femoro-femoral extracorporeal circulation (ECC) on the beating heart. A pericardial xenograft fixed within a stainless steel, balloon expandable stent (Edwards SAPIEN THV, Edwards Lifesciences) was used. Fifty-nine consecutive patients (81±6 years, 44 female) were operated on from 02/06 until 10/06 at 4 centers using fluoroscopic and echocardiographic visualization. Average EuroSCORE predicted risk for mortality was 27±14%. TAP valve positioning was performed successfully in 53 patients, 4 required early conversion to sternotomy. Implantation (23-mm valves in 19 and 26-mm valves in 40 patients) was performed on the beating heart during brief periods of rapid ventricular pacing. Thirty-one patients were operated on without cardiopulmonary bypass. Neither coronary artery obstruction nor migration of the prosthesis was observed, and all valves had good hemodynamic function. Echocardiography revealed minor paravalvular leakage in 26 patients (trace in 11, mild in 12, and severe in 3). Eight patients died in-hospital (13.6%) without any valve dysfunction. Actuarial survival was 75.7±5.9% at a follow-up interval of 110±77 days (range 1 to 255 days). Conclusions— TAP-AVI can be performed safely with good early results in high risk patients. Long-term valve performance as well as broader based applications of this promising approach will need to be studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
Cribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
Grube, E., Laborde, J. C., Gerckens, U., Felderhoff, T., Sauren, B., Buellesfeld, L., Mueller, R., Menichelli, M., Schmidt, T., Zickmann, B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.639450 · Cited by 655
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Sebagh, L., Bash, A., Nusimovici, D., Litzler, P. Y., Bessou, J.-P., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.11.026 · Cited by 644
Transapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience
Lichtenstein, S. V., Cheung, A., Ye, J., Thompson, C. R., Carere, R. G., Pasupati, S., & Webb, J. G. (2006) · Circulation · doi:10.1161/circulationaha.106.632927 · Cited by 561
Bonow, R. O., Carabello, B., de Leon, A. C., Edmunds, L. H., Fedderly, B. J., Freed, M. D., Gaasch, W. H., McKay, C. R., Nishimura, R. A., O’Gara, P. T., et al. (2000) · Indian Journal of Thoracic and Cardiovascular Surgery · doi:10.1007/s12055-000-0010-9 · Cited by 246
Prosthesis size and long-term survival after aortic valve replacement
Blackstone, E. H., Cosgrove, D. M., Jamieson, W. R. E., Birkmeyer, N. J., Lemmer, J. H., Miller, D. C., Butchart, E. G., Rizzoli, G., Yacoub, M., & Chai, A. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(03)00591-9 · Cited by 238
Minimally invasive transapical beating heart aortic valve implantation — proof of concept
Walther, T., Falk, V., Borger, M. A., Dewey, T., Wimmer-Greinecker, G., Schuler, G., Mack, M., & Mohr, F. W. (2007) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2006.10.034 · Cited by 230
Self-citationPatient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement☆
WALTHER, T., RASTAN, A., FALK, V, LEHMANN, S., GARBADE, J., FUNKAT, A., MOHR, F., & GUMMERT, J. (2006) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2006.04.007 · Cited by 186
Self-citation(2006) · Circulation · doi:10.1161/circulationaha.106.177303 · Cited by 174
Bauer, F., Eltchaninoff, H., Tron, C., Lesault, P., Agatiello, C. R., Nercolini, D. C., Dérumeaux, G., & Cribier, A. G. (2004) · Circulation · doi:10.1161/01.cir.0000134961.36773.d6 · Cited by 149
Twenty-year results of the Hancock II bioprosthesis.
Borger, M. A., Ivanov, J., Armstrong, S. M., Christie-Hrybinsky, D., Feindel, C. M., & David, T. E. (2006) · PubMed · Cited by 123
Self-citationHemodynamic stability during 17 years of the carpentier-edwards aortic pericardial bioprosthesis
Banbury, M. K., Cosgrove, D. M., Thomas, J. D., Blackstone, E. H., Rajeswaran, J., Okies, J. E., & Frater, R. (2002) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(02)03445-8 · Cited by 112
Valve surgery in octogenarians: a safe option with good medium-term results.
Chukwuemeka, A. O., Borger, M. A., Ivanov, J., Armstrong, S. M., Feindel, C. M., & David, T. E. (2006) · PubMed · Cited by 55
Self-citationCarroll, J. D. (2006) · Circulation · doi:10.1161/circulationaha.106.642264 · Cited by 11
Cited by
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationLeon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Self-citationRodés-Cabau, J., Webb, J. G., Cheung, A., Ye, J., Dumont, E., Feindel, C. M., Osten, M., Natarajan, M. K., Velianou, J. L., Martucci, G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.014 · Cited by 974
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Metadata
- Authors
- Walther, T., Simon, P., Dewey, T., Wimmer-Greinecker, G., Falk, V., Kasimir, M. T., Doss, M., Borger, M. A., Schuler, G., Glogar, D., Fehske, W., Wolner, E., Mohr, F. W., & Mack, M.
- Venue
- Circulation
- Published
- 2007-09-11
- Volume
- 116
- Issue
- 11_supplement
- Pages
- I240-5
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2158490705
- Cited by
- 618
- References
- 15
- FWCI
- 56.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.