Small or Large Isolation Areas Around the Pulmonary Veins for the Treatment of Atrial Fibrillation?: Results From a Prospective Randomized Study
Abstract
Background— Pulmonary vein (PV) isolation is a promising new treatment for atrial fibrillation (AF). We hypothesized that isolation of large areas around both ipsilateral PVs with verification of conduction block is more effective than the isolation of each individual PV. Methods and Results— A total of 110 patients, 67 with paroxysmal AF and 43 with persistent AF, were randomly assigned to undergo either isolation of each individual PV or isolation of large areas around both ipsilateral PVs. The isolation of each individual PV was an electrophysiologically guided, ostial segmental ablation with a 64-pole basket catheter or a 20-pole circular mapping catheter (group I). Isolation of large areas was performed around the 2 ipsilateral veins with a nonfluoroscopic navigation system and a circular 20-pole mapping catheter for verification of conduction block (group II). In both groups, an irrigated-tip ablation catheter (25 to 35 W) was used to achieve complete isolation. Procedure and ablation times were longer in group II, whereas fluoroscopic time was significantly shorter ( P ≤0.001). After a follow-up period of 15±4 months, 27 patients in group I (49%) and 37 patients in group II (67%) remained free of symptoms of AF and had no AF or atrial flutter during repetitive Holter monitoring without antiarrhythmic drug treatment after a single procedure ( P ≤0.05). Conclusions— The rate of success was significantly higher and fluoroscopy times were significantly lower in the group with large isolation areas around both ipsilateral PVs than in those who underwent individual PV isolation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
O'Neill, M. D., Wright, M., Knecht, S., Jais, P., Hocini, M., Takahashi, Y., Jonsson, A., Sacher, F., Matsuo, S., Lim, K. T., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp063 · Cited by 333
JAÏS, P., MATSUO, S., KNECHT, S., WEERASOORIYA, R., HOCINI, M., SACHER, F., WRIGHT, M., NAULT, I., LELLOUCHE, N., KLEIN, G., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01373.x · Cited by 255
Metadata
- Authors
- Arentz, T., Weber, R., Bürkle, G., Herrera, C., Blum, T., Stockinger, J., Minners, J., Neumann, F. J., & Kalusche, D.
- Venue
- Circulation
- Published
- 2007-06-19
- Volume
- 115
- Issue
- 24
- Pages
- 3057-3063
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1966613637
- Cited by
- 352
- References
- 0
- FWCI
- 17.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Small or Large Isolation Areas Around the Pulmonary Veins for the Treatment of Atrial Fibrillation?: Results From a Prospective Randomized Study. https://app.cochat.ai/papers/10.1161/circulationaha.107.690578
- The paper
- Arentz, T., Weber, R., Bürkle, G., Herrera, C., Blum, T., Stockinger, J., Minners, J., Neumann, F. J., & Kalusche, D. (2007). Small or Large Isolation Areas Around the Pulmonary Veins for the Treatment of Atrial Fibrillation?: Results From a Prospective Randomized Study. Circulation. https://doi.org/10.1161/circulationaha.107.690578
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.