The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Left Ventricular Untwisting Rate by Speckle Tracking Echocardiography
Open accessAbstract
Background— Recent studies validated the measurement of left ventricular (LV) untwisting rate (UR) by speckle tracking echocardiography. A few reports suggest that it may provide additional noninvasive insight into LV diastolic function. Methods and Results— Simultaneous echocardiographic imaging and LV pressure measurements (7F Millar catheters) were performed in 8 adult dogs. Loading conditions were altered by caval occlusion, whereas lusitropic state was changed by dobutamine and esmolol infusion. Inferior vena cava occlusion at all experimental stages (baseline, dobutamine, esmolol) led to a significant decrease ( P ≤0.01) in LV end-systolic volume (ESV) and a significant increase in UR ( P =0.03). The best relation was observed between LV UR and ESV ( r =−0.8, P <0.001). The clinical study was conducted in 67 patients (age 57±17 years, 19 women) undergoing simultaneous right heart catheterization and echocardiographic imaging, with 20 healthy subjects as a control group. There were 34 patients with ejection fraction (EF) <50% (25±9%), and 33 patients with normal EF and diastolic dysfunction (64±7%). Patients with LV systolic dysfunction had a significantly lower UR (−55 ο/s) in comparison with the control group (−89 ο/s) and patients with normal EF (−104 ο/s, P <0.05), and the determinants of LV UR were twist, ESV, and τ (r 2 =0.83, P <0.001). In patients with diastolic dysfunction and normal EF, twist and ESV were the independent predictors (r 2 =0.71, P <0.001). Conclusions— LV UR is reduced in patients with depressed EF, but not in those with diastolic dysfunction and normal EF, and is primarily determined by twist and ESV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Nagueh, S. F., Shah, G., Wu, Y., Torre-Amione, G., King, N. M. P., Lahmers, S., Witt, C. C., Becker, K., Labeit, S., & Granzier, H. L. (2004) · Circulation · doi:10.1161/01.cir.0000135591.37759.af · Cited by 486
Self-citationAlterations in the determinants of diastolic suction during pacing tachycardia
Bell, S. P., Nyland, L., Tischler, M. D., McNabb, M., Granzier, H., & LeWinter, M. M. (2000) · Circulation Research · doi:10.1161/01.res.87.3.235 · Cited by 190
Cited by
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.01.011 · Cited by 5,262
Self-citationRecommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Self-citationRecommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Self-citationNagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew082 · Cited by 2,425
Self-citationGeyer, H., Caracciolo, G., Abe, H., Wilansky, S., Carerj, S., Gentile, F., Nesser, H.-J., Khandheria, B., Narula, J., & Sengupta, P. P. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.02.015 · Cited by 1,102
Twist Mechanics of the Left Ventricle
Sengupta, P. P., Tajik, A. J., Chandrasekaran, K., & Khandheria, B. K. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.02.006 · Cited by 604
The Pathophysiology of Heart Failure With Normal Ejection Fraction
Tan, Y. T., Wenzelburger, F., Lee, E., Heatlie, G., Leyva, F., Patel, K., Frenneaux, M., & Sanderson, J. E. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.037 · Cited by 479
Wang, J., Khoury, D. S., Yue, Y., Torre-Amione, G., & Nagueh, S. F. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehn141 · Cited by 421
Self-citationLeft Ventricular Diastolic Function
Nagueh, S. F. (2020) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.10.038 · Cited by 304
Self-citationVentricular Geometry, Strain, and Rotational Mechanics in Pulmonary Hypertension
Puwanant, S., Park, M., Popović, Z. B., Tang, W. H. W., Farha, S., George, D., Sharp, J., Puntawangkoon, J., Loyd, J. E., Erzurum, S. C., et al. (2010) · Circulation · doi:10.1161/circulationaha.108.844340 · Cited by 240
Metadata
- Authors
- Wang, J., Khoury, D. S., Yue, Y., Torre-Amione, G., & Nagueh, S. F.
- Venue
- Circulation
- Published
- 2007-11-27
- Volume
- 116
- Issue
- 22
- Pages
- 2580-2586
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1994704174
- Cited by
- 195
- References
- 3
- FWCI
- 14.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.