The DOI matches its Crossref record.
Outcomes of Stent Thrombosis and Restenosis During Extended Follow-Up of Patients Treated With Bare-Metal Coronary Stents
Open accessAbstract
Background— Concern regarding risk of late thrombosis after “off-label” treatment with drug-eluting stents has prompted increased use of bare-metal stents (BMS) in current practice. The sequelae of late BMS failures, however, have been poorly characterized. Methods and Results— We performed a retrospective study of 4503 consecutive patients treated with at least 1 BMS and dual antiplatelet therapy between 1994 and 2000. The cumulative incidence of stent thrombosis was 0.5% at 30 days (95% CI, 0.3% to 0.7%), 0.8% at 1 year (95% CI, 0.6% to 1.1%), and 2.0% at 10 years (95% CI, 1.5% to 2.5%). Risk of late (30 days to 1 year) and very late (>1 year) BMS thrombosis was increased among patients considered off label for drug-eluting stent use ( P =0.024). When saphenous vein graft interventions were excluded, however, risk after off-label use was not significantly increased ( P =0.23). Other correlates included vein graft intervention, prior myocardial infarction (MI), peripheral vascular disease, and ulcerated lesion ( P <0.001). Mortality was markedly increased after late and very late BMS thrombosis, particularly during the first 30 days (hazard ratios, 22 [95% CI, 3.1 to 159] and 40 [95% CI, 15 to 107], respectively). The 10-year incidence of clinical restenosis was 18.1% (95% CI, 16.5% to 19.7%), presenting with MI in 2.1% (95% CI, 1.6% to 2.6%). Restenosis presenting with MI was associated with increased mortality compared with no restenosis (hazard ratio, 2.37; P <0.001) and with restenosis with a non-MI presentation (hazard ratio, 2.42; P <0.001). Conclusions— The incidence of BMS thrombosis and of MI caused by restenosis during extended follow-up is significant. Both complications are associated with mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Pathology of Neoatherosclerosis in Human Coronary Implants
Nakazawa, G., Otsuka, F., Nakano, M., Vorpahl, M., Yazdani, S. K., Ladich, E., Kolodgie, F. D., Finn, A. V., & Virmani, R. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.011 · Cited by 934
Drug-Eluting Coronary-Artery Stents
Stefanini, G. G., & Holmes, D. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1210816 · Cited by 728
Self-citationNakazawa, G., Finn, A. V., Joner, M., Ladich, E., Kutys, R., Mont, E. K., Gold, H. K., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2008) · Circulation · doi:10.1161/circulationaha.107.762047 · Cited by 611
Kirtane, A. J., Gupta, A., Iyengar, S., Moses, J. W., Leon, M. B., Applegate, R., Brodie, B., Hannan, E., Harjai, K., Jensen, L. O., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.826479 · Cited by 577
Bangalore, S., Kumar, S., Fusaro, M., Amoroso, N., Attubato, M. J., Feit, F., Bhatt, D. L., & Slater, J. (2012) · Circulation · doi:10.1161/circulationaha.112.097014 · Cited by 574
Metadata
- Authors
- Doyle, B., Rihal, C. S., O’Sullivan, C. J., Lennon, R. J., Wiste, H. J., Bell, M., Bresnahan, J., & Holmes, D. R.
- Venue
- Circulation
- Published
- 2007-11-20
- Volume
- 116
- Issue
- 21
- Pages
- 2391-2398
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2129425194
- Cited by
- 217
- References
- 0
- FWCI
- 23.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Outcomes of Stent Thrombosis and Restenosis During Extended Follow-Up of Patients Treated With Bare-Metal Coronary Stents. https://app.cochat.ai/papers/10.1161/circulationaha.107.707331
- The paper
- Doyle, B., Rihal, C. S., O’Sullivan, C. J., Lennon, R. J., Wiste, H. J., Bell, M., Bresnahan, J., & Holmes, D. R. (2007). Outcomes of Stent Thrombosis and Restenosis During Extended Follow-Up of Patients Treated With Bare-Metal Coronary Stents. Circulation. https://doi.org/10.1161/circulationaha.107.707331
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.