Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 577

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Safety and Efficacy of Drug-Eluting and Bare Metal Stents: Comprehensive Meta-Analysis of Randomized Trials and Observational Studies

Kirtane, Ajay J., Gupta, Anuj, Iyengar, Srinivas, Moses, Jeffrey W., Leon, Martin B., Applegate, Robert, Brodie, Bruce, Hannan, Edward, Harjai, Kishore, Jensen, Lisette Okkels, Park, Seung-Jung, Perry, Raphael, Racz, Michael, Saia, Francesco, Tu, Jack V., Waksman, Ron, Lansky, Alexandra J., Mehran, Roxana, Stone, Gregg W.·2009·Circulation

Abstract

Background— The safety and efficacy of drug-eluting stents (DES) among more generalized “real-world” patients than those enrolled in pivotal randomized controlled trials (RCTs) are controversial. We sought to perform a meta-analysis of DES studies to estimate the relative impact of DES versus bare metal stents (BMS) on safety and efficacy end points, particularly for non–Food and Drug Administration–labeled indications. Methods and Results— Comparative DES versus BMS studies published or presented through February 2008 with ≥100 total patients and reporting mortality data with cumulative follow-up of ≥1 year were identified. Data were abstracted from studies comparing DES with BMS; original source data were used when available. Data from 9470 patients in 22 RCTs and from 182 901 patients in 34 observational studies were included. RCT and observational data were analyzed separately. In RCTs, DES (compared with BMS) were associated with no detectable differences in overall mortality (hazard ratio [HR], 0.97; 95% confidence interval [CI], 0.81 to 1.15; P =0.72) or myocardial infarction (HR, 0.95; 95% CI, 0.79 to 1.13; P =0.54), with a significant 55% reduction in target vessel revascularization (HR, 0.45; 95% CI, 0.37 to 0.54; P <0.0001); point estimates were slightly lower in off-label compared with on-label analyses. In observational studies, DES were associated with significant reductions in mortality (HR, 0.78; 95% CI, 0.71 to 0.86), myocardial infarction (HR, 0.87; 95% CI, 0.78 to 0.97), and target vessel revascularization (HR, 0.54; 95% CI, 0.48 to 0.61) compared with BMS. Conclusions— In RCTs, no significant differences were observed in the long-term rates of death or myocardial infarction after DES or BMS use for either off-label or on-label indications. In real-world nonrandomized observational studies with greater numbers of patients but the admitted potential for selection bias and residual confounding, DES use was associated with reduced death and myocardial infarction. Both RCTs and observational studies demonstrated marked and comparable reductions in target vessel revascularization with DES compared with BMS. These data in aggregate suggest that DES are safe and efficacious in both on-label and off-label use but highlight differences between RCT and observational data comparing DES and BMS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.108.826479

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 577

Metadata

Authors
Kirtane, A. J., Gupta, A., Iyengar, S., Moses, J. W., Leon, M. B., Applegate, R., Brodie, B., Hannan, E., Harjai, K., Jensen, L. O., Park, S.-J., Perry, R., Racz, M., Saia, F., Tu, J. V., Waksman, R., Lansky, A. J., Mehran, R., & Stone, G. W.
Venue
Circulation
Published
2009-06-30
Volume
119
Issue
25
Pages
3198-3206
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2162162242
Cited by
577
References
4
FWCI
76.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Safety and Efficacy of Drug-Eluting and Bare Metal Stents: Comprehensive Meta-Analysis of Randomized Trials and Observational Studies. https://app.cochat.ai/papers/10.1161/circulationaha.108.826479
The paper
Kirtane, A. J., Gupta, A., Iyengar, S., Moses, J. W., Leon, M. B., Applegate, R., Brodie, B., Hannan, E., Harjai, K., Jensen, L. O., Park, S.-J., Perry, R., Racz, M., Saia, F., Tu, J. V., Waksman, R., Lansky, A. J., Mehran, R., & Stone, G. W. (2009). Safety and Efficacy of Drug-Eluting and Bare Metal Stents: Comprehensive Meta-Analysis of Randomized Trials and Observational Studies. Circulation. https://doi.org/10.1161/circulationaha.108.826479

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.