Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 364

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Catheter Ablation of Ventricular Tachycardia After Repair of Congenital Heart Disease: Electroanatomic Identification of the Critical Right Ventricular Isthmus

Zeppenfeld, Katja, Schalij, Martin J., Bartelings, Margot M., Tedrow, Usha B., Koplan, Bruce A., Soejima, Kyoko, Stevenson, William G.·2007·Circulation

Abstract

Background— Catheter ablation of ventricular tachycardia (VT) after repair of congenital heart disease can be difficult because of nonmappable VTs and complex anatomy. Insights into the relation between anatomic isthmuses identified by delineating unexcitable tissue using substrate mapping techniques and critical reentry circuit isthmuses might facilitate ablation. Methods and Results— Sinus rhythm voltage mapping of the right ventricle was performed in 11 patients with sustained VT after repair of congenital heart disease. Unexcitable tissue from patch material, valve annulus, or dense fibrosis, identified from bipolar voltage (<0.5 mV) and pacing threshold (>10 mA), was defined as an anatomic isthmus boundary bordering 4 isthmuses between (1) the tricuspid annulus and scar/patch in the anterior right ventricular outflow, (2) the pulmonary annulus and right ventricular free wall scar/patch, (3) the pulmonary annulus and septal scar/patch, and (4) the septal scar/patch and tricuspid annulus. The reentry circuit isthmuses of all induced 15 VTs (mean cycle length, 276±78 ms; 73% poorly tolerated), identified by activation, entrainment, and/or pace mapping, were located in an anatomic isthmus (11 of 15 VTs in anatomic isthmus 1). Transecting the anatomic isthmuses by ablation lesions abolished all VTs. During 30.4±29.3 months of follow-up, 91% of patients remained free of VT. Conclusions— Reentry circuit isthmuses in VT late after repair of congenital heart disease are located within anatomically defined isthmuses bordered by unexcitable tissue. The boundaries can be identified with 3-dimensional substrate mapping and connected by ablation lines during sinus rhythm. These findings should facilitate catheter and surgical ablation of stable and unstable VTs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.107.723551

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 364

Metadata

Authors
Zeppenfeld, K., Schalij, M. J., Bartelings, M. M., Tedrow, U. B., Koplan, B. A., Soejima, K., & Stevenson, W. G.
Venue
Circulation
Published
2007-11-13
Volume
116
Issue
20
Pages
2241-2252
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2115669561
Cited by
364
References
4
FWCI
9.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Catheter Ablation of Ventricular Tachycardia After Repair of Congenital Heart Disease: Electroanatomic Identification of the Critical Right Ventricular Isthmus. https://app.cochat.ai/papers/10.1161/circulationaha.107.723551
The paper
Zeppenfeld, K., Schalij, M. J., Bartelings, M. M., Tedrow, U. B., Koplan, B. A., Soejima, K., & Stevenson, W. G. (2007). Catheter Ablation of Ventricular Tachycardia After Repair of Congenital Heart Disease: Electroanatomic Identification of the Critical Right Ventricular Isthmus. Circulation. https://doi.org/10.1161/circulationaha.107.723551

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.