Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 202

The DOI matches its Crossref record.

Feasibility of Real-Time Magnetic Resonance Imaging for Catheter Guidance in Electrophysiology Studies

Open access
Nazarian, Saman, Kolandaivelu, Aravindan, Zviman, Menekhem M., Meininger, Glenn R., Kato, Ritsushi, Susil, Robert C., Roguin, Ariel, Dickfeld, Timm L., Ashikaga, Hiroshi, Calkins, Hugh, Berger, Ronald D., Bluemke, David A., Lardo, Albert C., Halperin, Henry R. · 2008 · Circulation

Abstract

Background— Compared with fluoroscopy, the current imaging standard of care for guidance of electrophysiology procedures, magnetic resonance imaging (MRI) provides improved soft-tissue resolution and eliminates radiation exposure. However, because of inherent magnetic forces and electromagnetic interference, the MRI environment poses challenges for electrophysiology procedures. In this study, we sought to test the feasibility of performing electrophysiology studies with real-time MRI guidance. Methods and Results— An MRI-compatible electrophysiology system was developed. Catheters were targeted to the right atrium, His bundle, and right ventricle of 10 mongrel dogs (23 to 32 kg) via a 1.5-T MRI system using rapidly acquired fast gradient-echo images (≈5 frames per second). Catheters were successfully positioned at the right atrial, His bundle, and right ventricular target sites of all animals. Comprehensive electrophysiology studies with recording of intracardiac electrograms and atrial and ventricular pacing were performed. Postprocedural pathological evaluation revealed no evidence of thermal injury to the myocardium. After proof of safety in animal studies, limited real-time MRI-guided catheter mapping studies were performed in 2 patients. Adequate target catheter localization was confirmed via recording of intracardiac electrograms in both patients. Conclusions— To the best of our knowledge, this is the first study to report the feasibility of real-time MRI-guided electrophysiology procedures. This technique may eliminate patient and staff radiation exposure and improve real-time soft tissue resolution for procedural guidance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.107.742452

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 202

Metadata

Authors
Nazarian, S., Kolandaivelu, A., Zviman, M. M., Meininger, G. R., Kato, R., Susil, R. C., Roguin, A., Dickfeld, T. L., Ashikaga, H., Calkins, H., Berger, R. D., Bluemke, D. A., Lardo, A. C., & Halperin, H. R.
Venue
Circulation
Published
2008-07-15
Volume
118
Issue
3
Pages
223-229
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2147842499
Cited by
202
References
0
FWCI
11.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feasibility of Real-Time Magnetic Resonance Imaging for Catheter Guidance in Electrophysiology Studies. https://app.cochat.ai/papers/10.1161/circulationaha.107.742452
The paper
Nazarian, S., Kolandaivelu, A., Zviman, M. M., Meininger, G. R., Kato, R., Susil, R. C., Roguin, A., Dickfeld, T. L., Ashikaga, H., Calkins, H., Berger, R. D., Bluemke, D. A., Lardo, A. C., & Halperin, H. R. (2008). Feasibility of Real-Time Magnetic Resonance Imaging for Catheter Guidance in Electrophysiology Studies. Circulation. https://doi.org/10.1161/circulationaha.107.742452

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.